| Parameter | Value |
|---|---|
| I/O ports | DT-4P, 4-pole, max. 8 A |
| Protocols | CAN SAE J1939, CAN Layer 2.0B |
| Standards | ECE R10 (E8) | ISO 13766-1 / -2 | EMC Directive (2014/30/EU) |
| Addressing | Node-ID 224 (0×E0h), Offset per Jumper +1…+15 |
| Protection | IP68 / IP69K (with MDC connection cables) |
| Transfer rate | 250/500 kbit/s |
| Actuator supply | DT 18-pole, A-coded |
| Mounting method | 3 hole screw mounting M5 |
| Sensor supply US | 8...32 V DC, max. 8 A |
| Temperature range | -40...+80 °C (storage temperature -40...+85 °C) |
| Actuator supply UA | 8...32 V DC, max. 2× 13 A |
| Diagnostic via BUS | per module and channel |
| Diagnostic via LED | per module and channel |
| Dimensions H×W×D | 35×97×265 mm |
| Communication status | via LED |
| Sensor-system supply | DT-4P, 4-pole, max. 8 A |
| Monitoring - no voltage | yes |
| Monitoring - under voltage | yes |
| Short-circuit and overload | yes |
| Switching current per output | max. 4 A |
| Reverse polarity protection module | yes |
| Product article number of manufacturer | DP-34044-1-000 |
Technical specifications and performance data