| Parameter | Value |
|---|---|
| Cross-section: 0.34 mm²; Length: 7 mm | |
| Step | 3.5 mm |
| Result | Approved Test |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Width [w] | 42 mm |
| frequency | 10 - 150 - 10 Hz |
| Height [h] | 13.25 mm |
| Length [l] | 23.35 mm |
| Shock Type | Semi-sinusoidal |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Peel Length | 10 mm |
| Plug Cycles | 25 |
| Sweep speed | 1 octave/min |
| Acceleration | 30g |
| Construction | Plug-in part |
| Product Line | COMBICON Connectors S |
| Product Type | Printed Circuit Board Connector |
| Locking system | Screw lock |
| Number of rows | 2 |
| Product Family | DFMC 1.5/.. -STF |
| Thermal stress | 100 °C/168 h |
| Clamping flange | Overhead clamping (screw) |
| Color (Housing) | Black (9005) |
| Connection type | Push-in spring connection |
| Nominal Section | 1.5 mm² |
| Number of poles | 10 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Connector System | COMBICON DFMC 1.5 |
| Contact material | Cu Alloy |
| Dimension Scheme | |
| Number of cycles | 25 |
| Corrosion fatigue | 0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle |
| Tightening torque | 0.2 Nm |
| Type of packaging | Boxed Packaging |
| Contact resistance | 2.1 mΩ |
| Nominal Current IN | 8 A |
| Nominal voltage UN | 160 V |
| Test Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Bearable AC voltage | 1.39 kV |
| Degree of pollution | 3 |
| Insulating material | PA |
| AWG Conductor Section | 24 ... 16 |
| Color (Drive Element) | Orange (2003) |
| Contact Resistance R1 | 2.1 mΩ |
| Contact Resistance R2 | 2.4 mΩ |
| Duration of the crash | 18 ms |
| Plug-in force approx. | 3 N |
| Nominal voltage (II/2) | 320 V |
| Number of poles tested | 20 |
| Sizing voltage (III/3) | 160 V |
| Test duration per axis | 2.5 h |
| Contact Connection Type | Female |
| Rigid conductor section | 0.2 mm² ... 1.5 mm² |
| Surface Characteristics | Malleable cast iron tinning |
| Recommended crimp pliers | 1212034 CRIMPFOX 6 |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Flexible conductor section | 0.2 mm² ... 1.5 mm² |
| Male gauge a x b / Diameter | 2.4 mm x 1.5 mm / 1.6 mm |
| Dimensioning voltage (III/2) | 160 V |
| Ambient Temperature (Service) | -40 °C ... 100 °C (depending on the rating curve) |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Connection Direction Driver/PCB | 0 ° |
| Nominal transient voltage (II/2) | 2.5 kV |
| Sizing Insulation Voltage (II/2) | 320 V |
| Nominal transient voltage (III/2) | 2.5 kV |
| Nominal transient voltage (III/3) | 2.5 kV |
| Sizing Insulation Voltage (III/2) | 160 V |
| Sizing Insulation Voltage (III/3) | 160 V |
| Minimum creepage line value (II/2) | 1.6 mm |
| Bearable shock voltage at sea level | 2.95 kV |
| Minimum creepage line value (III/2) | 1.5 mm |
| Minimum creepage line value (III/3) | 2 mm |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Dimensioning transient voltage (II/2) | 2.5 kV |
| Flammability class according to UL 94 | V0 |
| Power when unplugging by pole approx. | 2 N |
| Dimensioning Transient Voltage (III/2) | 2.5 kV |
| Dimensioning transient voltage (III/3) | 2.5 kV |
| Metal surface contact area (top layer) | Tin (4 - 8 μm Sn) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Metal surface of the terminal point (top layer) | Tin (4 - 8 μm Sn) |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| toe caps with insulated collar, according to DIN 46228-4 | Cross-section: 0.14 mm²; Length: 8 mm |
| Ball hardness test temperature according to EN 60695-10-2 | 125 °C |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Flexible conductor section with toe cap, with plastic sleeve | 0.25 mm² ... 0.75 mm² |
| toe caps without insulating collar, according to DIN 46228-1 | Cross-section: 0.25 mm²; Length: 7 mm |
| Flexible conductor section with toe cap, without plastic sleeve | 0.25 mm² ... 1.5 mm² |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 1.5 mm |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 1.5 mm |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 1.5 mm |
| Conductor Section/Conductor Type/Tensile Force Nominal Value/Actual Value | 0.2 mm² / rigid / > 10 N |
| Flammability number of GWFI incandescent filaments according to EN 60695-2-12 | 850 |
| Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13 | 775 |
Technical specifications and performance data