Key Specifications
Note:WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Type:Feed-through header
Pitch:5.08 mm
Screw:0708263 DFK-MSTB SS for housing walls of up to 6 mm thick
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
NoteWEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
TypeFeed-through header
Pitch5.08 mm
Screw0708263 DFK-MSTB SS for housing walls of up to 6 mm thick
ResultTest passed
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Frequency10 - 150 - 10 Hz
Width [w]62.32 mm
Height [h]15.9 mm
Length [l]18.2 mm
Pin layoutLinear pinning
Sweep speed1 octave/min
Acceleration5g (60.1 Hz ... 150 Hz)
Product lineCOMBICON Connectors M
Product typeFeed-through header
Hole diameter1.4 mm
Mounting typeWave soldering
No. of cycles25
SpecificationIEC 60512-1-1:2002-02
Number of rows1
Pin dimensions1 x 1 mm
Product familyDFK-MSTBVA 2,5/..-G
Thermal stress105 °C/168 h
Color (Housing)green (6021)
Mounting flangewithout
Test directionsX-, Y- and Z-axis
Article revision02
Contact materialCu alloy
Corrosive stress0.2 dm3SO2on 300 dm3/40 °C/1 cycle
Installed height12 mm
Tightening torque0.3 Nm
Type of packagingpacked in cardboard
Contact resistance2.5 mΩ
Nominal current IN12 A
Nominal voltage UN320 V
Notes on operationIn accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load.
Dimensional drawing
Insulating materialPBT
Number of positions9
Number of potentials9
Rated voltage (II/2)400 V
Contact resistance R12.5 mΩ
Contact resistance R22.5 mΩ
Number of connections9
Rated voltage (III/2)320 V
Rated voltage (III/3)250 V
Solder pin length [P]3.9 mm
Test duration per axis2.5 h
Surface characteristicsTin-plated
Insulating material groupIIIa
Solder pins per potential1
CTI according to IEC 60112225
Rated surge voltage (II/2)4 kV
Tested number of positions16
Insertion/withdrawal cycles25
Rated surge voltage (III/2)4 kV
Rated surge voltage (III/3)4 kV
Ambient temperature (assembly)-5 °C ... 100 °C
Ambient temperature (operation)-40 °C ... 105 °C (dependent on the derating curve)
Rated insulation voltage (II/2)400 V
Rated insulation voltage (III/2)320 V
Rated insulation voltage (III/3)250 V
minimum creepage distance (II/2)4 mm
Power-frequency withstand voltage2.21 kV
minimum creepage distance (III/2)3.2 mm
minimum creepage distance (III/3)4 mm
Withdraw strength per pos. approx.6 N
Insertion strength per pos. approx.8 N
Relative humidity (storage/transport)30 % ... 70 %
Flammability rating according to UL 94V0
Impulse withstand voltage at sea level4.8 kV
Metal surface contact area (top layer)Tin (3 - 5 µm Sn)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Comparative tracking index (IEC 60112)CTI 225
Metal surface soldering area (top layer)Tin (3 - 5 µm Sn)
Metal surface contact area (middle layer)Nickel (1 - 3 µm Ni)
Contact holder in insertRequirements >20 NTest passed
Metal surface soldering area (middle layer)Nickel (1 - 3 µm Ni)
Insulation resistance, neighboring positions> 5 MΩ
minimum clearance value - non-homogenous field (II/2)3 mm
minimum clearance value - non-homogenous field (III/2)3 mm
minimum clearance value - non-homogenous field (III/3)3 mm

Product Description

Cable pass housing, nominal section: 2.5 mm², color: green, nominal current: 12 A, nominal voltage (III/2): 320 V, contact surface: Tin, contact type: Male, number of potentials: 9, number of rows: 1,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide