| Parameter | Value |
|---|---|
| GTIN | 4017918099367 |
| Orderkey | 2964050 |
| (Coil side) | 120 W (at 24 V DC - up to 35°) |
| Catalog page | Page 439 (C-5-2017) |
| Depth (Note) | 56 mm |
| Packing unit | 10 pc |
| Width (Note) | 6.2 mm |
| Height (Note) | 80 mm |
| Torque (General) | 0.5 Nm |
| Country of origin | CN (China) |
| Note (Contact side) | Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place. |
| Custom tariff number | 85364190 |
| Screw thread (General) | M3 |
| Contact type (Coil side) | 1 N/O contact |
| Connection name (General) | Coil side |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| Type of note (Contact side) | Note on application |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | AgNi, hard gold-plated |
| Operating mode (Contact side) | 100% operating factor |
| (Connection data output side) | EN 50178 |
| Net weight (SAP) (Contact side) | 22.71 g |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | 5 A |
| Min. switching current (Coil side) | 1 mA |
| Type of switch contact (Coil side) | Double contact |
| Torque (Connection data input side) | 0.5 Nm |
| Assembly instructions (Contact side) | In rows with zero spacing |
| Weight per Piece (excluding packing) | 22.710 g |
| Conductor cross section AWG (General) | 24 ... 14 |
| Maximum switching voltage (Coil side) | 250 V AC |
| Minimum switching voltage (Coil side) | 0.1 V |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Mechanical service life (Contact side) | approx. 2x 107cycles |
| Conductor cross section solid (General) | 0.2 mm² ... 2.5 mm² |
| Limiting continuous current (Coil side) | 3 A (5 A up to 35°C at 24 V DC) |
| Protective circuit (Ambient conditions) | Bridge rectifier Bridge rectifier |
| Insulation (Connection data output side) | Basic insulation |
| Screw thread (Connection data input side) | M3 |
| Typical release time (Ambient conditions) | 15 ms |
| Conductor cross section flexible (General) | 0.2 mm² ... 2.5 mm² |
| Typical response time (Ambient conditions) | 5 ms |
| Ambient temperature (operation) (Dimensions) | -20 °C ... 50 °C |
| Connection name (Connection data input side) | Contact side |
| Nominal input voltage UN (Ambient conditions) | 24 V AC/DC |
| Stripping length (Connection data input side) | 8 mm |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Connection method (Connection data input side) | Screw connection |
| Operating voltage display (Ambient conditions) | Yellow LED |
| Typical input current at UN (Ambient conditions) | 6.5 mA |
| Degree of pollution (Connection data output side) | 2 |
| Interrupting rating (ohmic load) max. (Coil side) | 72 W (at 24 V DC) |
| Overvoltage category (Connection data output side) | III |
| Standards/regulations (Connection data output side) | IEC 60664 |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C |
| Test voltage relay winding/relay contact (Contact side) | 2 kV AC (50 Hz, 1 min.) |
| Conductor cross section AWG (Connection data input side) | 24 ... 14 |
| Conductor cross section solid (Connection data input side) | 0.2 mm² ... 2.5 mm² |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.1 |
| Power dissipation for nominal condition (Ambient conditions) | 0.16 W |
| Conductor cross section flexible (Connection data input side) | 0.2 mm² ... 2.5 mm² |
| Connection in acc. with standard (Connection data output side) | CUL |
Technical specifications and performance data
Installation and operation guide