Service time: Monday to Friday 9:00-18:00
DEK-OV-24DC/ 24DC/ 3/AKT - DEK-OV- 24DC/ 24DC/ 3/AKT 2964296 PHOENIX CONTACT Solid-state relay terminal block
In Stock Hot Product

DEK-OV-24DC/ 24DC/ 3/AKT

DEK-OV- 24DC/ 24DC/ 3/AKT 2964296 PHOENIX CONTACT Solid-state relay terminal block

$0.00USD
3589 in stock
Key Specifications
:Surge protection
Color:green (RAL 6021)
Depth:56 mm
Width:6.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Surge protection
Colorgreen (RAL 6021)
Depth56 mm
Width6.2 mm
Height80 mm
InsulationBasic insulation
ApplicationOutput function
Product typeSolid-state relay module
Screw threadM3
Assembly notein rows with zero spacing
Mounting typeDIN rail mounting
Operating mode100% operating factor
Output circuit2-conductor, floating
Product familyDEK
Article revision12
Pollution degree2
Stripping length8 mm
Connection methodScrew connection
Mounting positionany
Tightening torque0.5 Nm
Protective circuitReverse polarity protection
Input voltage range19.2 V DC ... 28.8 V DC
Note on applicationUse of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Output voltage range3 V DC ... 30 V DC
Overvoltage categoryIII
Standards/regulationsIEC 60947-5-1
Typical response time40 µs
Typical turn-off time200 µs
Contact switching type1 N/O contact
Transmission frequency300 Hz
Design of digital outputelectronic
Nominal input voltage UN24 V DC
Operating voltage displayYellow LED
Conductor cross section AWG24 ... 14
Limiting continuous current3 A (see derating curve)
Test voltage (Input/output)2.5 kV AC (Input/output)
Typical input current at UN7 mA
Date of last data management03.05.2024
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Ambient temperature (operation)-20 °C ... 60 °C
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Input voltage range in reference to UN0.8 ... 1.2
Ambient temperature (storage/transport)-20 °C ... 70 °C
Maximum power dissipation for nominal condition0.17 W
Voltage drop at max. limiting continuous current≤ 0.2 V
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8

Product Description

Solid state power relay terminal for actuators, input: 24 V DC, output: 3-30 V DC/3 A, terminal width 6.2 mm
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top