Service time: Monday to Friday 9:00-18:00
DEK-OE-5DC/ 5DC/100KHZ-G - DEK-OE- 5DC/ 5DC/100KHZ-G 2964542 PHOENIX CONTACT Solid-state relay terminal block
In Stock Hot Product

DEK-OE-5DC/ 5DC/100KHZ-G

DEK-OE- 5DC/ 5DC/100KHZ-G 2964542 PHOENIX CONTACT Solid-state relay terminal block

$0.00USD
4312 in stock
Key Specifications
GTIN:4017918131005
Orderkey:2964542
(General):EN 50178
Catalog page:Page 451 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4017918131005
Orderkey2964542
(General)EN 50178
Catalog pagePage 451 (C-5-2017)
Depth (Note)56 mm
Packing unit10 pc
Width (Note)6.2 mm
Height (Note)80 mm
Country of originCN (China)
Custom tariff number85364190
Insulation (General)Basic insulation
Torque (Output data)0.5 Nm
(Ambient conditions)Surge protection
Screw thread (Output data)M3
Output circuit (Input data)3-conductor push-pull, ground referenced
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (Output data)Input side
Degree of pollution (General)2
Overvoltage category (General)II
Quiescent current (Input data)8.5 mA
Stripping length (Output data)8 mm
(Connection data, output side)EN 50178
Connection method (Output data)Screw connection
Standards/regulations (General)IEC 60664
Type of protection (Input data)Surge protection
Output voltage range (Input data)4 V DC ... 18 V DC
Note (Connection data, output side)Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Torque (Connection data, input side)0.5 Nm
Weight per Piece (excluding packing)21.900 g
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Type of protection (Ambient conditions)Reverse polarity protection
Input voltage range (Ambient conditions)2.5 V DC ... 6 V DC
Limiting continuous current (Input data)50 mA
Conductor cross section AWG (Output data)24 ... 12
Protective circuit/component (Input data)Suppressor diode
Screw thread (Connection data, input side)M3
Typical response time (Ambient conditions)1 µs
Typical turn-off time (Ambient conditions)2 µs
Conductor cross section solid (Output data)0.2 mm² ... 4 mm²
Transmission frequency (Ambient conditions)100 kHz
Type of note (Connection data, output side)Note on application
Ambient temperature (operation) (Dimensions)-20 °C ... 60 °C
Connection name (Connection data, input side)Output side
Nominal input voltage UN (Ambient conditions)5 V DC
Operating mode (Connection data, output side)100% operating factor
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section flexible (Output data)0.2 mm² ... 2.5 mm²
Operating voltage display (Ambient conditions)Yellow LED
Stripping length (Connection data, input side)8 mm
Connection method (Connection data, input side)Screw connection
Mounting position (Connection data, output side)any
Typical input current at UN (Ambient conditions)8 mA
Protective circuit/component (Ambient conditions)Polarity protection diode
Degree of pollution (Connection data, output side)2
Overvoltage category (Connection data, output side)II
Ambient temperature (storage/transport) (Dimensions)-20 °C ... 70 °C
Assembly instructions (Connection data, output side)In rows with zero spacing
Standards/regulations (Connection data, output side)IEC 60664
Test voltage input/output (Connection data, output side)2.5 kV AC
Conductor cross section AWG (Connection data, input side)24 ... 12
Conductor cross section solid (Connection data, input side)0.2 mm² ... 4 mm²
Input voltage range in reference to UN (Ambient conditions)0.5 ... 1.2
Voltage drop at max. limiting continuous current (Input data)≤ 1.2 V DC
Conductor cross section flexible (Connection data, input side)0.2 mm² ... 2.5 mm²
Switching threshold "0" signal in reference to UN (Ambient conditions)≤ 0.3
Switching threshold "1" signal in reference to UN (Ambient conditions)≥ 0.5

Product Description

Input solid-state relay, with DC voltage output phase shift, 100 kHz transfer frequency, with indicator light and protection circuit in input and output circuit, input: 5 V DC, output: 4 - 18 V DC/50
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide