| Parameter | Value |
|---|---|
| Step | 2.5 mm |
| Result | Approved Test |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Width [w] | 21.4 mm |
| frequency | 10 - 150 - 10 Hz |
| Height [h] | 14.8 mm |
| Length [l] | 20 mm |
| Shock Type | Semi-sinusoid |
| Peel Length | 3 mm |
| Plug Cycles | 25 |
| Sweep speed | 1 octave/min |
| Acceleration | 30g |
| Product Line | CONNEXIS Connectors XS |
| Product Type | Printed Circuit Board Connector |
| Locking system | Lace lock |
| Number of rows | 2 |
| Product Family | DD21PC 0.85/ |
| Thermal stress | 105 °C/168 h |
| Clamping flange | Lace Flange |
| Color (Housing) | Black (9005) |
| Connection type | Crimp connection |
| Note on contact | These are connectors without switching capability (COC) according to DIN EN 61984. In the event of use as prescribed, they must not be plugged in or unplugged under voltage or load. |
| Number of poles | 16 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Dimension Scheme | |
| Number of cycles | 25 |
| Corrosion fatigue | 0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle |
| Type of packaging | Boxed Packaging |
| Contact resistance | 2.6 mΩ |
| Nominal Current IN | 5 A |
| Nominal voltage UN | 160 V |
| Test Specification | DIN EN 60068-2-70:1996-07 |
| Bearable AC voltage | 1.39 kV |
| Degree of pollution | 3 |
| Insulating material | PBT |
| AWG Conductor Section | 28 ... 18 |
| Contact Resistance R1 | 2.6 mΩ |
| Contact Resistance R2 | 2.6 mΩ |
| Duration of the crash | 11 ms |
| Plug-in force approx. | 6 N |
| Nominal voltage (II/2) | 200 V |
| Number of poles tested | 20 |
| Sizing voltage (III/3) | 40 V |
| Test duration per axis | 2.5 h |
| Insulating material group | Ii |
| CTI according to IEC 60112 | 400 ≤ CTI |
| Dimensioning voltage (III/2) | 160 V |
| Ambient Temperature (Service) | -55 °C ... 105 °C (depending on the rating curve) |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Connection Direction Driver/PCB | 0 ° |
| Nominal transient voltage (II/2) | 2.5 kV |
| Sizing Insulation Voltage (II/2) | 200 V |
| Nominal transient voltage (III/2) | 2.5 kV |
| Nominal transient voltage (III/3) | 2.5 kV |
| Sizing Insulation Voltage (III/2) | 160 V |
| Sizing Insulation Voltage (III/3) | 40 V |
| Minimum creepage line value (II/2) | 1.5 mm |
| Bearable shock voltage at sea level | 2.95 kV |
| Minimum creepage line value (III/2) | 1.5 mm |
| Minimum creepage line value (III/3) | 1.6 mm |
| Insulation Resistance Adjacent Poles | > 5 MΩ |
| Dimensioning transient voltage (II/2) | 2.5 kV |
| Flammability class according to UL 94 | V0 |
| Power when unplugging by pole approx. | 6 N |
| Dimensioning Transient Voltage (III/2) | 2.5 kV |
| Dimensioning transient voltage (III/3) | 2.5 kV |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI ≥400 to <600 |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 1.5 mm |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 1.5 mm |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 1.5 mm |
| Conductor Section/Conductor Type/Tensile Force Nominal Value/Actual Value | AWG 28 / flexible / > 11 N |
Technical specifications and performance data