Service time: Monday to Friday 9:00-18:00
DC1-34014FB-A20N - DC1-34014FB-A20N 169490 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 14 A, 5.5 kW, IP20/NEMA ..
In Stock Hot Product

DC1-34014FB-A20N

DC1-34014FB-A20N 169490 EATON ELECTRIC Variable frequency drive, 400 V AC, 3-phase, 14 A, 5.5 kW, IP20/NEMA ..

$0.00USD
3691 in stock
Key Specifications
:
Note:
Depth:
Width:
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Note
Depth
Width
Height
Supply
Storageϑ
Altitude
Function
Standards
Efficiencyη
Frame size
Main choke
Power loss
Fitted with
Sine filter
UL File No.
motor choke
CSA File No.
Feature NameFeature Value
Motor feeder
Power Wiring
Suitable for
Analog inputs
Mains voltage
Power section
Product range
Relay outputs
150 % OverloadP
Analog outputs
Apparent power
Certifications
Digital inputs
Operation Mode
Digital outputs
Frequency rangefLN
Mains contactor
Mains frequency
At 150% overloadIe
Braking function
Depth (EF000049)175 mm
Output Frequencyf2
Supply frequencyfLN
Width (EF000008)131 mm
Climatic proofingρw
DC braking torque
Environment (EMC)
Height (EF000040)273 mm
Mounting position
Product Standards
Reference voltageUs
Type of converter
With control unit
Braking resistance
DC link connection
Production quality
UL (Class CC or J)
With PC connection
Ambient temperature
Max. Voltage Rating
Switching frequencyfPWM
Degree of Protection
Rated output voltage
System configuration
10 % duty factor (DF)
20 % duty factor (DF)
40 % duty factor (DF)
Assigned motor rating
Max. output frequency
Number of phases input
Output voltage with VeU2
With optical interface
IEC (Type B, gG), 150 %
Mains voltage (50/60Hz)ULN
Number of phases output
Standard braking torque
UL Category Control No.
Mains voltage (EF006780)380 V
Measuring output current
Radio interference level
Degree of protection (IP)
Mains switch-on frequency
Rated operational current
Rated operational voltageUe
Connection to SmartWire-DT
Mains frequency (EF006783)50/60 Hz
maximum motor cable lengthI
operation (150 % overload)ϑ
North America Certification
Number of HW-interfaces USB
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for LON
Type of converter (EF006978)U converter
4-quadrant operation possible
Input current (150% overload)ILN
Integrated braking resistance
Number of HW-interfaces other
With PC connection (EF006107)Yes
Fieldbus connection (optional)
Interface/field bus (built-in)
Max. output voltage (EF009560)400 V
Number of HW-interfaces RS-232
Number of HW-interfaces RS-422
Number of HW-interfaces RS-485
Radio interference class (EMC)
Supporting protocol for MODBUS
Supporting protocol for SERCOS
Supporting protocol for TCP/IP
Part group reference (e.g. DIL)
Supporting protocol for SUCONET
With control element (EF001538)Yes
Max. output frequency (EF007350)500 Hz
Note about max. starting current
Number of HW-interfaces PROFINET
Number of HW-interfaces parallel
Overload current (150% overload)IL
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
maximum permissible cable lengthI
150 % overload (CT/IH, at 50 °C)
Number of phases input (EF007117)3
Protection against direct contact
Supporting protocol for DeviceNet
Supporting protocol for PROFIsafe
With optical interface (EF003028)No
Number of HW-interfaces serial TTY
Number of phases output (EF006998)3
Number of digital inputs (EF001992)4
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for SafetyBUS p
minimum external braking resistanceRmin
Degree of protection (IP) (EF005474)IP20
Number of analogue inputs (EF001994)2
Number of digital outputs (EF001993)1
Output power at rated output voltage
Specially designed for North America
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Frequency resolution (setpoint value)Δf
Nominal output current I2N (EF009561)14 A
Number of analogue outputs (EF001995)1
max. starting current (High Overload)IH
Number of HW-interfaces USB (EF003025)1
Supporting protocol for ASI (EF003051)No
Supporting protocol for CAN (EF003053)Yes
Supporting protocol for KNX (EF003055)No
Supporting protocol for LON (EF003017)No
Apparent power at rated operation 400 VS
Apparent power at rated operation 480 VS
Supporting protocol for INTERBUS-Safety
4-quadrant operation possible (EF006803)No
Application in industrial area permitted
Number of HW-interfaces other (EF003027)0
Number of interfaces PROFINET (EF006932)0
Relative symmetric net current tolerance
Supporting protocol for DeviceNet Safety
Integrated breaking resistance (EF007293)Yes
Number of HW-interfaces RS-232 (EF003021)0
Number of HW-interfaces RS-422 (EF003022)0
Number of HW-interfaces RS-485 (EF003023)1
Supporting protocol for BACnet (EF011944)No
Supporting protocol for Modbus (EF003057)Yes
Supporting protocol for SERCOS (EF006657)No
Supporting protocol for TCP/IP (EF003050)No
Supporting protocol for other bus systems
Relative symmetric net frequency tolerance
Supporting protocol for SUCONET (EF003060)No
Number of HW-interfaces industrial Ethernet
Number of HW-interfaces parallel (EF003026)0
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS (EF003054)No
Supporting protocol for PROFIBUS (EF003052)No
Supporting protocol for DeviceNet (EF003059)No
Supporting protocol for PROFIsafe (EF007526)No
Number of HW-interfaces serial TTY (EF003024)0
Supporting protocol for EtherNet/IP (EF007521)No
Supporting protocol for PROFINET IO (EF007525)No
Supporting protocol for SafetyBUS p (EF007527)No
Switch-on threshold for the braking transistorUDC
Braking torque with external braking resistance
Supporting protocol for Data-Highway (EF003058)No
Supporting protocol for PROFINET CBA (EF007524)No
Safety device (fuse or miniature circuit-breaker)
Max. output at linear load at rated output voltage
Supporting protocol for INTERBUS-Safety (EF006662)No
Application in industrial area permitted (EF007294)Yes
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety (EF007520)No
Maximum leakage current to ground (PE) without motorIPE
Note regarding radio interference suppression filter
Supporting protocol for other bus systems (EF003062)No
Max. output at quadratic load at rated output voltage
Relative symmetric net frequency tolerance (EF007454)10 %
Application in domestic- and commercial area permitted
Heat dissipation at rated operational current Ie=150 %PV
Number of HW-interfaces industrial Ethernet (EF003020)0
Supporting protocol for Foundation Fieldbus (EF007522)No
Max. output at linear load at rated output voltage (EF007364)5.5 kW
Supporting protocol for AS-Interface Safety at Work (EF007519)No
Max. output at quadratic load at rated output voltage (EF007366)5.5 kW
Application in domestic- and commercial area permitted (EF007295)Yes
Radio interference suppression filter, low leakage currents (external, 150 %)

Product Description

Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase,
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top