| Parameter | Value |
|---|---|
| Type | Mounting direction |
| 1-conduit | Front-side mounting |
| Contact gap | 2×2 mm min. |
| Durability2 | Mechanical:1,000,000 operations min.Electrical:500,000 operations min. (10 A at 250 VAC, resistive load) |
| Full stroke | 23 mm min. |
| Operating speed | 0.1 m/s to 0.5 m/s |
| Rated frequency | 50/60 Hz |
| Vertical mounting | |
| Ambient temperature | Operating:-40 to 80°C (with no icing) |
| Horizontal mounting | |
| Operating frequency | 30 operations/min max. |
| 1NC/1NO (slow-action) | 2NC (slow-action) |
| Degree of protection1 | IP67 (EN60947-5-1) |
| Direct opening force3 | 19.61 N min. (EN60947-5-1) |
| Direct opening travel3 | 20 mm min. (EN60947-5-1) |
| Adjustable mounting(horizontal) | |
| Conditional short-circuit current | 100 A (EN60947-5-1) |
| Protection against electric shock | Class I (with ground terminal) |
| Pollution degree (operating environment) | 3 (EN60947-5-1) |
| Conventional enclosed thermal current (Ith) | 20 A (EN60947-5-1) |
Technical specifications and performance data