| Parameter | Value |
|---|---|
| Link | Crimp Connection |
| Step | 3.81 mm |
| Result | Test passed |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Frequency | 10 - 150 - 10 Hz |
| Packaging | Packed in carton |
| Width [w] | 47 mm |
| Height [h] | 12.7 mm |
| Length [l] | 33.6 mm |
| Sweep Speed | 1 octave/min |
| Color (Case) | Black (9005) |
| No. of poles | 5 |
| Note for use | All laboratory tests were performed in conjunction with the crimp contacts listed as accessories. |
| Product Line | CONNEXIS Connectors S |
| Product Type | Step-through connector |
| Bore diameter | 3.6 mm |
| Clamping Type | Snap lock |
| Fixing flange | Snap-in tab |
| Number of rows | 1 |
| Product Family | D31H 2.2/.. -PT |
| Fixed AC voltage | 1.39 kV |
| Mass Resistivity | 5 mΩ |
| Number of cycles | 25 |
| Rated Current IN | 8 A |
| Rated voltage UN | 160 V |
| Manoeuvring cycles | 25 |
| Test Specification | DIN EN 60512-15-1:2009-03 |
| Contact Information | According to DIN EN 61984, these connectors have no switching power (COC). For intended use, they must not be plugged in or disconnected while they are still live or under load. |
| Degree of pollution | 3 |
| Dimensioned Drawing | |
| Insulation material | PBT |
| Mass Resistivity R1 | 5 mΩ |
| Mass Resistivity R2 | 5 mΩ |
| Sizing voltage (II/2) | 320 V |
| Number of poles tested | 10 |
| Sizing voltage (III/2) | 160 V |
| Sizing voltage (III/3) | 160 V |
| Test duration per axle | 2.5 h |
| Stress due to corrosion | 0.2 dm3KNOW2on 300 dm3/40 °C/1 cycle |
| Insulation Material Group | II |
| CTI according to IEC 60112 | 400 ≤ CTI |
| Conductor cross-section AWG | 28 ... 14 |
| Rated Impulse Voltage (II/2) | 2.5 kV |
| Minimum creepage value (II/2) | 2.2 mm |
| Rated impulse voltage (III/2) | 2.5 kV |
| Rated impulse voltage (III/3) | 2.5 kV |
| Sizing Impulse Voltage (II/2) | 2.5 kV |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Minimum creepage value (III/2) | 1.5 mm |
| Minimum creepage value (III/3) | 2.2 mm |
| Rated Isolation Voltage (II/2) | 320 V |
| Sizing Impulse Voltage (III/2) | 2.5 kV |
| Sizing impulse voltage (III/3) | 2.5 kV |
| Tensile force per pole approx. | 6 N |
| Ambient temperature (operating) | -55 °C ... 105 °C (depending on the derating curve) |
| Rated Isolation Voltage (III/2) | 160 V |
| Insertion force per pole approx. | 6 N |
| Rated insulation voltage (III/3) | 160 V |
| Stress due to the effect of heat | 105 °C/168 h |
| Length of the section to be stripped | 4.5 mm |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Combustibility class according to UL 94 | V0 |
| Vertical impulse tension above sea level | 2.95 kV |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Insulation Resistance Between Contiguous Poles | > 5 MΩ |
| Minimum creepage value - inhomogeneous range (II/2) | 1.5 mm |
| Minimum creepage value - inhomogeneous range (III/2) | 1.5 mm |
| Minimum clearance value - inhomogeneous range (III/3) | 1.5 mm |
| Areas of application for contact holdersApplication >20 N | Test passed |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI ≥400 up to <600 |
| Conductor cross-section/conductor type/tensile force nominal value/actual value | AWG 28 / flexible / > 11 N |
Technical specifications and performance data
Installation and operation guide