| Parameter | Value |
|---|---|
| 5 m (Electronic non-contact door monitoring system) | D40A-1C5 |
| Item (Electronic non-contact door monitoring system) | G9SX-NS202-_/G9SX-NSA222-T03-_ |
| Material (Electronic non-contact door monitoring system) | PBT resin |
| Instantaneous (Electronic non-contact door monitoring system) | OFF-delayed5 |
| Safety input8 (Electronic non-contact door monitoring system) | Operating voltage: 20.4 VDC to 26.4 VDC, internal impedance: approx. 2.8 kΩ |
| Classification (Electronic non-contact door monitoring system) | Auxiliary outputs |
| LED indicators (Electronic non-contact door monitoring system) | Actuator not detected (red); actuator detected (yellow) |
| Mounting method (Electronic non-contact door monitoring system) | M4 screws |
| Safety outputs2 (Electronic non-contact door monitoring system) | Auxiliary outputs3 |
| Standard models (Electronic non-contact door monitoring system) | Semiconductor outputs1 |
| Auxiliary output (Electronic non-contact door monitoring system) | PNP transistor outputLoad current: 100 mA max. |
| Shock resistance (Electronic non-contact door monitoring system) | 300 m/s2min. |
| Connection cables (Electronic non-contact door monitoring system) | 2 m, 5 m |
| Power consumption (Electronic non-contact door monitoring system) | 0.6 W max. |
| Auxiliary outputs7 (Electronic non-contact door monitoring system) | 24 VDC, 10 mA (PNP open-collector outputs) |
| 2 (Semi-conductors) (Electronic non-contact door monitoring system) | 3.0 s |
| Degree of protection (Electronic non-contact door monitoring system) | IP67 |
| Rated supply voltage (Electronic non-contact door monitoring system) | 24 VDC |
| Vibration resistance (Electronic non-contact door monitoring system) | 10 to 55 to 10 Hz (single amplitude: 0.75 mm, double amplitude: 1.5 mm) |
| Spring-cage terminals (Electronic non-contact door monitoring system) | G9SX-NSA222-T03-RC |
| Operatingcharacteristics6 (Electronic non-contact door monitoring system) | Operating distance OFF®ON |
| Differential travel (max.) (Electronic non-contact door monitoring system) | 20% of operating distance |
| Operating distance ON®OFF (Electronic non-contact door monitoring system) | 15 mm max. |
| Ambient operating temperature (Electronic non-contact door monitoring system) | −10 to 55°C (no icing or condensation) |
| Number of connectable switches (Electronic non-contact door monitoring system) | 30 max. (wiring length: 100 m max.) |
| Pigtail with M12 connector 4-pole (Electronic non-contact door monitoring system) | D40A-1C015-F |
| Instantaneous safety outputOFF-delayed safety output (Electronic non-contact door monitoring system) | P channel MOS FET transistor outputLoad current: 0.8 A DC max. |
| Example: Wiring a single switchNote:The auxiliary output load current must be 10 mA max. (Electronic non-contact door monitoring system) | Example: Wiring multiple switchesConnect up to 30 Non-contact door switches |
Technical specifications and performance data
Installation and operation guide