| Parameter | Value |
|---|---|
| Feature Name | Feature Value |
| (Accessories) | 6 |
| 20 (Accessories) | 30 |
| 30 (Accessories) | 50 |
| Depth (EF000049) | 101 mm |
| Width (EF000008) | 35 mm |
| Height (EF000040) | 130 mm |
| ⬛ (Accessories) | W4S1-05C |
| Item (Accessories) | XS6W-6LSZH8SS_CM-_ |
| Type (Accessories) | Connector |
| Shape (Accessories) | Functions |
| Redundancy (EF003156) | Yes |
| IO link master (EF007298) | No |
| Rated current (Accessories) | 1 A (at 50°C) |
| Transmission rate (EF003271) | 100000 kBit/s |
| Ethernet socket (Accessories) | RJ45 socket |
| Radio standard GSM (EF008524) | No |
| Radio standard GPRS (EF008523) | No |
| Radio standard UMTS (EF008525) | No |
| Withstand voltage (Accessories) | 1,000 VDC for 60 s (leakage current: 1 mA max.) |
| With optical interface (EF003028) | No |
| Protective structure (Accessories) | IP20 |
| Radio standard Bluetooth (EF007178) | No |
| CAN (Specifications & ordering info) | 1 × CAN |
| Type of data transmission (EF008225) | Serial |
| With potential separation (EF003272) | Yes |
| Radio standard WLAN 802.11 (EF007179) | No |
| SIL according to IEC 61508 (EF009889) | None |
| Type (Specifications & ordering info) | Ports |
| GP-IB (Specifications & ordering info) | Master/Slave selectable |
| Number of HW-interfaces CAN (EF017563) | 0 |
| Number of HW-interfaces USB (EF003025) | 0 |
| Supporting protocol for ASI (EF003051) | No |
| Supporting protocol for CAN (EF003053) | No |
| Supporting protocol for KNX (EF003055) | No |
| Supporting protocol for LON (EF003017) | No |
| Serial (Specifications & ordering info) | 1 × RS-232C +1 × RS-422/RS-485 |
| Ethernet field-mount plugs (Accessories) | Plastic RJ45 |
| Number of HW-interfaces other (EF003027) | 1 |
| Number of interfaces PROFINET (EF006932) | 1 |
| Suitable for safety functions (EF001597) | No |
| Ambient storage temperature (Accessories) | −20 to 60°C |
| CompoNet (Specifications & ordering info) | 4-wire, data + power to slaves (Master) |
| Ethernet (Specifications & ordering info) | 1 × 100 Base-Tx |
| Ethernet installation cable (Accessories) | none |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Supporting protocol for Modbus (EF003057) | No |
| Supporting protocol for SERCOS (EF006657) | No |
| Supporting protocol for TCP/IP (EF003050) | Yes |
| DeviceNet (Specifications & ordering info) | 1 × CAN |
| Supporting protocol for SUCONET (EF003060) | No |
| Ambient operating temperature (Accessories) | −20 to 60°C |
| CompoBus/S (Specifications & ordering info) | 2-wire (Master) |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Supporting protocol for EtherCAT (EF017564) | No |
| Supporting protocol for INTERBUS (EF003054) | No |
| Supporting protocol for PROFIBUS (EF003052) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |
| Description (Specifications & ordering info) | Connection type |
| EtherNet/IP (Specifications & ordering info) | 1 × 100 Base-Tx |
| Explosion safety category for gas (EF003997) | None |
| PROFIBUS-DP (Specifications & ordering info) | 1 × RS-485 (Slave) |
| PROFINET IO (Specifications & ordering info) | 1 × 100 Base-TxPROFINET IO controller |
| Supporting protocol for DeviceNet (EF003059) | No |
| Supporting protocol for PROFIsafe (EF007526) | No |
| Explosion safety category for dust (EF003998) | None |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Optical HPCF (Specifications & ordering info) | - |
| Ambient installation temperature (Accessories) | 0 to 50°C |
| Supporting protocol for EtherNet/IP (EF007521) | No |
| Supporting protocol for PROFINET IO (EF007525) | Yes |
| Supporting protocol for SafetyBUS p (EF007527) | No |
| Supporting protocol for Data-Highway (EF003058) | No |
| Supporting protocol for PROFINET CBA (EF007524) | No |
| Controller link (Specifications & ordering info) | 2-wire twisted pair |
| Supporting protocol for INTERBUS-Safety (EF006662) | No |
| Supporting protocol for DeviceNet Safety (EF007520) | No |
| Supporting protocol for other bus systems (EF003062) | No |
| Certified for UL hazardous location class I (EF017622) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 1 |
| Supporting protocol for Foundation Fieldbus (EF007522) | No |
| Certified for UL hazardous location class II (EF017625) | No |
| Certified for UL hazardous location class III (EF017627) | No |
| Performance level according to EN ISO 13849-1 (EF007399) | Level a |
| Certified for UL hazardous location division 1 (EF017628) | No |
| Certified for UL hazardous location division 2 (EF017629) | No |
| Optical graded-index fiber (Specifications & ordering info) | - |
| Supporting protocol for AS-Interface Safety at Work (EF007519) | No |
| Certified for UL hazardous location group D (propane) (EF017636) | No |
| Certified for UL hazardous location group B (hydrogen) (EF017633) | No |
| Certified for UL hazardous location group C (ethylene) (EF017635) | No |
| Certified for UL hazardous location group A (acetylene) (EF017632) | No |
| Certified for UL hazardous location group E (metal dusts) (EF017637) | No |
| Certified for UL hazardous location group F (carbonaceous dusts) (EF017638) | No |
| Certified for UL hazardous location group G (non-conductive dusts) (EF017639) | No |
| Controller link repeater unit (wire to wire) (Specifications & ordering info) | Screw - Screw |
| Controller link PCI board with support software (Specifications & ordering info) | PCI, ST connectors |
| Controller link repeater unit (wire to HPCF fiber) (Specifications & ordering info) | Screw - HPCF connector |
| PROFINET IO + ModBus/TCP to Modbus/RTU (RS-485) Gateway. (Specifications & ordering info) | 3 × RJ45 to screw clamp terminals |
| Controller link repeater unit (wire to graded-index glass fiber) (Specifications & ordering info) | Screw - ST connector |
| RS-232C to RS-422/RS-485 signal converter. Mounts directly on serial port. (Specifications & ordering info) | 9-pin D-sub to screw clamp terminals |
| PROFIBUS DP to RS-422/RS-485 Serial Gateway. User-configurable, with Omron protocols built-in. (Specifications & ordering info) | 9-pin D-sub to screw clamp terminals |
Technical specifications and performance data