| Parameter | Value |
|---|---|
| Weight | 100g |
| Emission | Red |
| Approvals | CE, cULus |
| Dimensions | 107mm x 20mm x 36mm |
| Beams space | 10mm |
| Connections | M12 plug |
| Output type | NPN+PNP |
| Load current | 100mA |
| LED indicators | green: power supply-alignment; red: dark/light status |
| number of rays | 6 |
| Leakage current | ≤100μA |
| Output Function | NO/NC |
| Housing Material | Aluminim |
| EMC compatibility | EN 60947-5-2 |
| Operating Voltage | 16…30Vdc |
| controlled height | 69mm |
| Function Principle | Retroreflective polarized area sensor |
| Max ripple content | ≤ 10% |
| Output voltage drop | 3Vdc @ 100mA |
| Switching frequency | 400Hz |
| Thermal drift of Sr | ≤10% |
| Active Head Material | PMMA |
| Degree of protection | IP67 |
| Supplied Accessories | RL106G reflector + fixing kit (ST151) |
| Operating temperature | -10°C…+ 55° C (without freeze) |
| Shocks and vibrations | IEC EN 60947-5-2 / 7.4 |
| No-Load supply current | 100mA |
| Sensitivity adjustment | Teach in: fine < 3s; standard > 6s |
| Nominal sensing distance | 0,2 … 4,5m (with RL106G) |
| Short-circuit protection | Yes (autoreset) |
| minimum detectable object | 3…6mm @ 2m RL106G - 3…10mm @ 4,5m RL106G |
| Reverse Polarity Protection | Yes |
| Interference to external light | 5000lux (fluorescent lamp); 50000lux (sun light) |
| Time delay before availability | 300ms |
| Impulsive Overvoltage Protection | Yes |
Technical specifications and performance data
Installation and operation guide