| Parameter | Value |
|---|---|
| for installation in electric vehicles (EVs) | |
| Depth | 117.65 mm |
| Width | 117.65 mm |
| Height | 90 mm |
| Number | 3 (PE, DC+, DC-) |
| General | For DC contacts, a cap is included in the scope of delivery. |
| Altitude | 4000 m (above sea level) |
| Cable type | Individual Drivers |
| Technology | Combined Charging System |
| Plug Cycles | > 10000 |
| Sensor Type | Pt 1000 |
| application | for direct current (DC) charging |
| Cable length | 3 m |
| Codification | 4.7 kΩ (between PE and PP) |
| Product Type | Vehicle Entry |
| Charging Mode | Mode 4 |
| Fixing screws | M6 |
| Rated Current | 200 A DC |
| Charging power | 200 kW |
| Product Family | CHARX connect universal |
| Cable Structure | 2 x 70 mm² |
| Color (Housing) | Black (9005) |
| Crash Detection | existent |
| Insertion Force | < 100 N |
| Line Resistance | ≤ 0.259 Ω/km |
| Nominal voltage | 1000 V DC |
| Attachment point | 2 sensors on DC contacts |
| Charging current | 200 A |
| Separation Force | < 100 N |
| Type of mounting | Front and rear wall mounting (Front tilt possible from 0 to 90 degrees) |
| Charging Standard | CCS Type 2 |
| Operating voltage | 24 V |
| Material (Housing) | Plastic |
| Cable Outer Diameter | 17.9 mm ±0.3 mm |
| Color (Plug-in Face) | Black (9005) |
| Fixing Hole Diameter | 6.70 mm (ø) |
| Single Driver, Color | OG |
| AWG Conductor Section | (Converted according to IEC) |
| Charging Current Type | DC |
| Insulation resistance | > 200 MΩ |
| Reverse Motor Current | max. 0.5 A |
| Single driver, material | Silicone |
| Temperature Measurement | DC contacts: 2x PT1000 (DIN EN 60751) |
| Standards/Specifications | DIN EN 60751 |
| Material (Surface contacts) | Silver |
| Note on the number of poles | 4 poles |
| Recommended Adaptation Time | 600 ms |
| Type of Signal Transmission | Pulse amplitude modulation with Powerline communication modulated according to ISO/IEC 15118 / DIN SPEC 70121 |
| Ambient Temperature (Service) | -30 °C ... 50 °C |
| Lifespan of connection cycles | > 10000 charge cycles |
| Typical Lockout Motor Current | 0.05 A |
| Emergency mechanical unlocking | existent |
| Note about the connection type | Crimped, non-detachable connection |
| Position of the locking actuator | To the right |
| Max. dwell time with locking current | 1 sec |
| Protection Index (Vehicle Load Input) | IP55 (plugged in, the protection rating in working and plugged in can only be guaranteed if both connection elements are original Phoenix Contact products or equivalent standard products) |
| Maximum Voltage for Blockage Detection | 30 V |
| Ambient Temperature (Storage/Transport) | -40 °C ... 85 °C |
| Screws included in the scope of delivery | none |
| Possible supply voltage range in the motor | 22 V ... 26 V |
| Pause time after an inbound or outbound journey | 3 s |