| Parameter | Value |
|---|---|
| Step | 5 mm |
| note | Complies with WEEE/RoHS, no thread-like materials according to IEC 60068-2-82/JEDEC JESD 201 |
| Result | Test passed |
| Process | Reflow/wave soldering |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| ESD Level | (D) Anti-static |
| Frequency | 10 - 150 - 10 Hz |
| Packaging | Tape width 32 mm |
| Width [w] | 12.8 mm |
| Height [h] | 14.6 mm |
| Length [l] | 8.57 mm |
| Pin Layout | Linear Pinning |
| Shank sizes | 1 x 1 mm |
| Sweep Speed | 1 octave/min |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Color (Case) | Black (9005) |
| Product Line | COMBICON Connectors M |
| Product Type | Basic socket for printed circuit boards |
| Bore diameter | 1.6 mm |
| Mounting type | TTHR / wave soldering |
| Article review | 01 |
| Belt width [W] | 32 mm |
| Number of rows | 1 |
| Product Family | CCVA 2.5/.. -G |
| Surface Finish | Galvanic tin plating |
| Number of poles | 2 |
| Test Directions | X, Y, and Z axis |
| Contact Material | Cu Alloy |
| Fixed AC voltage | 2.21 kV |
| Mass Resistivity | 1.2 mΩ |
| Number of cycles | 25 |
| Rated Current IN | 12 A |
| Rated voltage UN | 320 V |
| Coil diameter [A] | 330 mm |
| Type of packaging | Transparent bag |
| Manoeuvring cycles | 25 |
| Note for Operation | According to DIN EN 61984, COMBICON connectors are connectors without switchable power (COC). For use in accordance with the intended use, they must not be switched on or disconnected while they are still live or under load. |
| Test Specification | DIN EN 60512-1-1:2003-01 |
| Dimensioned Drawing | |
| Installation Height | 12 mm |
| Insulation material | LCP |
| Mass Resistivity R1 | 1.2 mΩ |
| Mass Resistivity R2 | 1.2 mΩ |
| Welding Process Data | Machining in reflow processes in accordance with IEC 60068-2-58 or DIN EN 61760-1 (updated version)Moisture Sensitive Level (MSL) = 1 according to IPC/JEDEC J-STD-020-C |
| Sizing voltage (II/2) | 400 V |
| Weld Shank Length [P] | 2.6 mm |
| Number of poles tested | 24 |
| Sizing voltage (III/2) | 320 V |
| Sizing voltage (III/3) | 250 V |
| Test duration per axle | 2.5 h |
| Coil external size [W2] | 38.4 mm |
| Reflow Soldering Cycles | 3 |
| Stress due to corrosion | 0.2 dm3KNOW2on 300 dm3/40 °C/1 cycle |
| Moisture Sensitive Level | MSL 1 |
| Insulation Material Group | IIIa |
| CTI according to IEC 60112 | 175 |
| Rated Impulse Voltage (II/2) | 4 kV |
| Classification Temperature Tc | 260 °C |
| Minimum creepage value (II/2) | 4 mm |
| Rated impulse voltage (III/2) | 4 kV |
| Rated impulse voltage (III/3) | 4 kV |
| Sizing Impulse Voltage (II/2) | 4 kV |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Minimum creepage value (III/2) | 3.2 mm |
| Minimum creepage value (III/3) | 4 mm |
| Rated Isolation Voltage (II/2) | 400 V |
| Sizing Impulse Voltage (III/2) | 4 kV |
| Sizing impulse voltage (III/3) | 4 kV |
| Tensile force per pole approx. | 6 N |
| Ambient temperature (operating) | -40 °C ... 100 °C (depending on derating curve) |
| Rated Isolation Voltage (III/2) | 320 V |
| Insertion force per pole approx. | 8 N |
| Rated insulation voltage (III/3) | 250 V |
| Stress due to the effect of heat | 100 °C/168 h |
| Number of Welding Pins per Potential | 1 |
| Metal Surface Weld Area (Middle Layer) | Nickel (1.3 - 3 μm Ni) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Combustibility class according to UL 94 | V0 |
| Vertical impulse tension above sea level | 4.8 kV |
| Metal surface contact area (middle layer) | Nickel (1.3 - 3 μm Ni) |
| Relative humidity (transport and storage) | 30 % ... 70 % |
| Metal Surface Welding Area (Surface Layer) | Tin (3 - 5 μm Sn) |
| Metal surface contact zone (surface layer) | Tin (3 - 5 μm Sn) |
| Insulation Resistance Between Contiguous Poles | > 5 MΩ |
| Minimum creepage value - inhomogeneous range (II/2) | 3 mm |
| Minimum creepage value - inhomogeneous range (III/2) | 3 mm |
| Minimum clearance value - inhomogeneous range (III/3) | 3 mm |
| Areas of application for contact holdersApplication >20 N | Test passed |
| Resistance to surface currents (DIN EN 60112 (VDE 0303-11)) | CTI 175 |
Technical specifications and performance data