| Parameter | Value |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| Note | The wires are marked and fitted with ferrules |
| Pitch | 2.54 mm |
| General | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Altitude | ≤ 2000 m |
| Shielded | no |
| Cable type | 10X0.14 [PVC] |
| Cable length | 4 m |
| Halogen-free | no |
| Product type | System cable |
| UL AWM Style | 2464/1061 |
| IDC/FLK14 (1) | () = black |
| IDC/FLK14 (2) | () = brown |
| IDC/FLK14 (3) | () = red |
| IDC/FLK14 (4) | () = orange |
| IDC/FLK14 (5) | () = yellow |
| IDC/FLK14 (6) | () = green |
| IDC/FLK14 (7) | () = blue |
| IDC/FLK14 (8) | () = violet |
| Conductor type | Round cable set |
| AWG signal line | 26 |
| Cable resistance | ≤ 145 Ω/km (20 °C) |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| Connection method | Single wires |
| Cross section AWG | (converted acc. to IEC) |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Suitable I/O card | AXL F DI16... |
| Conductor material | Tin-plated Cu litz wires |
| Max. bending cycles | 5000 |
| Number of positions | 10 |
| Degree of protection | IP00 |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Number of connections | 1 |
| External sheath, color | gray |
| Nominal operating mode | 100% operating factor |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Outer sheath, material | Semi-rigid PVC |
| Conductor cross section | 10x 0.14 mm² |
| External cable diameter | 6.1 mm ±0.4 mm |
| Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Stripping length (Sheath) | 150 mm |
| Conductor cross section AWG | 26 |
| Insertion/withdrawal cycles | > 50 |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| Conductor structure signal line | 7x 0.16 mm |
| Connection in acc. with standard | based on IEC 60603-13 |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Smallest bending radius, fixed installation | 52 mm |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Smallest bending radius, movable installation | 98 mm |
Technical specifications and performance data
Installation and operation guide