| Parameter | Value |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| red | D-SUB37 (8) = () |
| Note | The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end. |
| blue | D-SUB37 (7) = () |
| gray | D-SUB37 (5) = () |
| pink | D-SUB37 (6) = () |
| Pitch | 2.77 mm |
| black | D-SUB37 (9) = () |
| brown | D-SUB37 (2) = () |
| green | D-SUB37 (3) = () |
| white | D-SUB37 (1) = () |
| violet | D-SUB37 (10) = () |
| yellow | D-SUB37 (4) = () |
| Altitude | ≤ 2000 m |
| Shielded | yes |
| red-blue | D-SUB37 (12) = () |
| brown-red | D-SUB37 (24) = () |
| gray-blue | D-SUB37 (37) = () |
| gray-pink | D-SUB37 (11) = () |
| green-red | D-SUB37 (33) = () |
| white-red | D-SUB37 (23) = () |
| Cable type | 37X0.25 [PVC] |
| brown-blue | D-SUB37 (22) = () |
| gray-brown | D-SUB37 (18) = () |
| gray-green | D-SUB37 (27) = () |
| green-blue | D-SUB37 (31) = () |
| pink-brown | D-SUB37 (20) = () |
| pink-green | D-SUB37 (29) = () |
| white-blue | D-SUB37 (21) = () |
| white-gray | D-SUB37 (17) = () |
| white-pink | D-SUB37 (19) = () |
| yellow-red | D-SUB37 (34) = () |
| brown-black | D-SUB37 (26) = () |
| brown-green | D-SUB37 (14) = () |
| green-black | D-SUB37 (35) = () |
| white-black | D-SUB37 (25) = () |
| white-green | D-SUB37 (13) = () |
| yellow-blue | D-SUB37 (32) = () |
| yellow-gray | D-SUB37 (28) = () |
| yellow-pink | D-SUB37 (30) = () |
| Cable length | 2 m |
| Halogen-free | no |
| Product type | System cable |
| Screw thread | UNC 4-40 |
| UL AWM Style | 2464/1061 |
| white-yellow | D-SUB37 (15) = () |
| yellow-black | D-SUB37 (36) = () |
| yellow-brown | D-SUB37 (16) = () |
| Conductor type | Assembled shielded round cable |
| AWG signal line | 24 |
| Article revision | 04 |
| Cable resistance | ≤ 80 Ω/km (at 20 °C) |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| Connection method | Single wires |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Tightening torque | 0.2 Nm |
| Conductor material | Bare Cu litz wires |
| Current (Per path) | ≤ 2 A (Uncoiled, see derating) |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Number of positions | 37 |
| Degree of protection | IP20 |
| Insulation resistance | ≥ 20 MΩ*km (at 20 °C) |
| Number of connections | 1 |
| External sheath, color | gray |
| Nominal operating mode | 100% operating factor |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Outer sheath, material | Semi-rigid PVC |
| Conductor cross section | 37x 0.25 mm² |
| External cable diameter | 10.80 mm ±0.5 mm |
| Stripping length (Sheath) | 150 mm |
| Insertion/withdrawal cycles | > 200 |
| Wire diameter incl. insulation | 1.2 mm ±0.05 mm |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| Conductor structure signal line | 14x 0.15 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Connection in acc. with standard | IEC 60807-2 |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Smallest bending radius, fixed installation | 90 mm |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Smallest bending radius, movable installation | 170 mm |
Technical specifications and performance data
Installation and operation guide