| Parameter | Value |
|---|---|
| GTIN | 4055626620589 |
| Note | Made to Order (non-returnable) |
| Orderkey | 3281105 |
| Packing unit | 50 pc |
| Pitch (General) | 7 mm |
| Width (General) | 15.5 mm |
| Length (General) | 42 mm |
| Country of origin | IN (India) |
| Custom tariff number | 85369010 |
| Height NS 35/15 (General) | 41 mm |
| Height NS 35/7,5 (General) | 33.5 mm |
| Color (Key Commercial Data) | black |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 8 mm ... 9 mm |
| Connection method (Dimensions) | Push-in connection |
| Potentials (Key Commercial Data) | 1 |
| Connection method (Connection data) | Push-in connection |
| Nominal current IN (Connection data) | 16 A |
| Nominal voltage UN (Connection data) | 600 V |
| Weight per Piece (excluding packing) | 22.220 g |
| Open side panel (Key Commercial Data) | Yes |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Maximum load current (Connection data) | 16 A |
| Number of levels (Key Commercial Data) | 1 |
| Nominal current IN (Key Commercial Data) | 17.5 A |
| Nominal voltage UN (Key Commercial Data) | 690 V |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PC |
| Rated surge voltage (Key Commercial Data) | 8 kV |
| Maximum load current (Key Commercial Data) | 17.5 A (The maximum load current must not be exceeded by the total current of all connected conductors.) |
| Overvoltage category (Key Commercial Data) | III |
| Nominal cross section (Key Commercial Data) | 1.5 mm² |
| Number of connections (Key Commercial Data) | 4 |
| Conductor cross section AWG max. (Dimensions) | 16 |
| Conductor cross section AWG min. (Dimensions) | 26 |
| Connection in acc. with standard (Dimensions) | IEC 60947-7-1 |
| Conductor cross section solid max. (Dimensions) | 1.5 mm² |
| Conductor cross section solid min. (Dimensions) | 0.14 mm² |
| Insulating material group (Key Commercial Data) | IIIa |
| Conductor cross section flexible max. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.14 mm² |
| Connection in acc. with standard (Connection data) | JIS 8207-7-1 |
| Ambient temperature (operation) (Key Commercial Data) | -40 °C ... 110 °C |
| Conductor cross section flexible max. (Connection data) | 1.25 mm² |
| Conductor cross section flexible min. (Connection data) | 0.5 mm² |
| Max. AWG conductor cross section, flexible (Dimensions) | 16 |
| Min. AWG conductor cross section, flexible (Dimensions) | 26 |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Connection cross sections directly pluggable (Connection data) | 0.5 mm 1.2 mm |
| Connection in acc. with standard (Connection data (JIS standard)) | IEC 60947-7-1 |
| Single-wire/terminal point, solid diameter max. (Connection data) | 1.2 mm |
| Single-wire/terminal point, solid diameter min. (Connection data) | 0.5 mm |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 0.56 W |
| Flammability rating according to UL 94 (Connection data (JIS standard)) | V0 |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 0.75 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Connection data) | 0.75 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Connection data) | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Connection data) | 1.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Connection data) | 0.5 mm² |
Technical specifications and performance data
Installation and operation guide