| Parameter | Value |
|---|---|
| EMC (17.5 mm wide conductive level controller) | EN 61326-11 |
| Item (17.5 mm wide conductive level controller) | K8DT-LS1 |
| Type (17.5 mm wide conductive level controller) | Application |
| Weight (17.5 mm wide conductive level controller) | Approx. 100 g |
| 24 VAC/DC (17.5 mm wide conductive level controller) | Relay: SPDT contact output |
| Separator (17.5 mm wide conductive level controller) | To prevent contact between electrodes, one pole |
| Indicators (17.5 mm wide conductive level controller) | Power PWR: Green, Output (OUT): Yellow |
| Front cover (17.5 mm wide conductive level controller) | |
| Output form (17.5 mm wide conductive level controller) | Relay: SPDT contact outputTransistor: Open collector |
| Minimum load (17.5 mm wide conductive level controller) | 5 VDC, 10 mA (reference values) |
| Case material (17.5 mm wide conductive level controller) | PC, UL 94 V-0 |
| Rated voltage (17.5 mm wide conductive level controller) | 24 VDC (maximum voltage: 26.4 VDC) |
| Response time (17.5 mm wide conductive level controller) | Approx. 0.1 to 10 s (variable) |
| 100 to 240 VAC (17.5 mm wide conductive level controller) | Relay: SPDT contact output |
| Inductive load (17.5 mm wide conductive level controller) | 1 A at 250 VAC0.2 A at 48 VDC |
| Mounting piece (17.5 mm wide conductive level controller) | Electrode Holder for the PS Series |
| Electrical life (17.5 mm wide conductive level controller) | 5 A at 250 VAC or 30 VDC: 50,000 operations3 A at 250 VAC or 30 VDC: 100,000 operations |
| Length of cable (17.5 mm wide conductive level controller) | 100 m max. (fully insulated 3-core 0.75-mm2 cabtyre cable, 600 V) |
| Maximum current (17.5 mm wide conductive level controller) | 50 mA DC |
| Mechanical life (17.5 mm wide conductive level controller) | 10 million operations min. |
| Protective cover (17.5 mm wide conductive level controller) | Electrode holders for the PS or BF series |
| Reset resistance (17.5 mm wide conductive level controller) | 250 kΩ max. |
| Safety standards (17.5 mm wide conductive level controller) | UL 61010-1 (Listing), Korean Radio Waves Act (Act 10564), CCC: GB14048.5 |
| Power consumption (17.5 mm wide conductive level controller) | 1.8 VA/1 W max. |
| Applicablestandards (17.5 mm wide conductive level controller) | Approved standards |
| Storage temperature (17.5 mm wide conductive level controller) | −25 to 65°C (with no condensation or icing) |
| Degree of protection (17.5 mm wide conductive level controller) | Terminals: IP20 |
| Operating resistance (17.5 mm wide conductive level controller) | 10k to 100 kΩ (variable) |
| Power supply voltage (17.5 mm wide conductive level controller) | 24 VAC 50/60 Hz, 24 VDC |
| Output contact ratings (17.5 mm wide conductive level controller) | Resistive load |
| Operating voltage range (17.5 mm wide conductive level controller) | 85% to 110% of rated voltage |
| Size in mm (H × W × D) (17.5 mm wide conductive level controller) | 90×17.5×90 |
| Transistor outputratings (17.5 mm wide conductive level controller) | Contact form |
| Voltage across electrodes (17.5 mm wide conductive level controller) | 5 V p-p (Approx. 20 Hz) |
| Transistor: Open collector (17.5 mm wide conductive level controller) | K8DT-LS1TA |
| For areas with limited space (17.5 mm wide conductive level controller) | PS-31 SUS304, 300 mm |
| Ambient operating temperature (17.5 mm wide conductive level controller) | −20 to 60°C (with no condensation or icing) |
| For liquids with low resistance (17.5 mm wide conductive level controller) | BF-1 |
| For resistance against corrosion (17.5 mm wide conductive level controller) | BS-1T |
| When mounting strength is required (17.5 mm wide conductive level controller) | BF-3/-5 |
| Electrode holders/underwater electrodes (17.5 mm wide conductive level controller) | For general-purpose use, such as water supply lines |
| To prevent contact between electrodes, five poles (17.5 mm wide conductive level controller) | F03-14 5P |
| To prevent contact between electrodes, three poles (17.5 mm wide conductive level controller) | F03-14 3P |
| For installation at long distances from the liquid level (17.5 mm wide conductive level controller) | PH-1/-2 |
| For resistance to high-temperature or high-pressure liquids (17.5 mm wide conductive level controller) | BS-1 |
| Purified water service, industrial water, sewage, and weak alkaline solutions (17.5 mm wide conductive level controller) | F03-60 SUS316 |
| Electrode rods (Set with the connection nuts, lock nuts, and tightening screws) (17.5 mm wide conductive level controller) | Purified water service, industrial water, and sewage |
Technical specifications and performance data
Installation and operation guide