Key Specifications
Note:WEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
Type:Standard
Pitch:5.08 mm
Result:Test passed
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
NoteWEEE/RoHS-compliant, free of whiskers according to IEC 60068-2-82/JEDEC JESD 201
TypeStandard
Pitch5.08 mm
ResultTest passed
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Frequency10 - 150 - 10 Hz
Width [w]55.88 mm
Height [h]11.8 mm
Length [l]12 mm
Pin layoutLinear pinning
Sweep speed1 octave/min
Acceleration5g (60.1 Hz ... 150 Hz)
Product lineCOMBICON Connectors M
Product typePCB headers
Hole diameter1.4 mm
Mounting typeWave soldering
No. of cycles25
SpecificationIEC 60512-1-1:2002-02
Number of rows1
Pin dimensions1 x 1 mm
Product familyBCH-H
Thermal stress105 °C/168 h
Color (Housing)signal grey (7004)
Mounting flangewithout
Test directionsX-, Y- and Z-axis
Article revision01
Contact materialCu alloy
Corrosive stress0.2 dm3SO2on 300 dm3/40 °C/1 cycle
Installed height8.57 mm
Type of packagingpacked in cardboard
Contact resistance2.1 mΩ
Nominal current IN12 A
Nominal voltage UN320 V
Notes on operationIn accordance with IEC 61984, COMBICON connectors have no switching power (COC). During designated use, they must not be plugged in or disconnected when carrying voltage or under load.
Dimensional drawing
Insulating materialPA
Number of positions11
Number of potentials11
Rated voltage (II/2)400 V
Contact resistance R12.1 mΩ
Contact resistance R22.1 mΩ
Number of connections11
Rated voltage (III/2)320 V
Rated voltage (III/3)250 V
Solder pin length [P]3.23 mm
Test duration per axis2.5 h
Surface characteristicsTin-plated
Insulating material groupI
Solder pins per potential1
CTI according to IEC 60112600
Rated surge voltage (II/2)4 kV
Tested number of positions24
Insertion/withdrawal cycles25
Rated surge voltage (III/2)4 kV
Rated surge voltage (III/3)4 kV
Ambient temperature (assembly)-5 °C ... 100 °C
Ambient temperature (operation)-40 °C ... 105 °C (dependent on the derating curve)
Rated insulation voltage (II/2)400 V
Rated insulation voltage (III/2)320 V
Rated insulation voltage (III/3)250 V
minimum creepage distance (II/2)3 mm
Power-frequency withstand voltage2.21 kV
minimum creepage distance (III/2)3 mm
minimum creepage distance (III/3)3.2 mm
Withdraw strength per pos. approx.6 N
Insertion strength per pos. approx.8 N
Relative humidity (storage/transport)30 % ... 70 %
Flammability rating according to UL 94V0
Impulse withstand voltage at sea level4.8 kV
Metal surface contact area (top layer)Tin (4 - 8 µm Sn)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Comparative tracking index (IEC 60112)CTI 600
Metal surface soldering area (top layer)Tin (4 - 8 µm Sn)
Metal surface contact area (middle layer)Nickel (1.3 - 4 µm Ni)
Contact holder in insertRequirements >20 NTest passed
Metal surface soldering area (middle layer)Nickel (1.3 - 4 µm Ni)
Insulation resistance, neighboring positions> 5 MΩ
minimum clearance value - non-homogenous field (II/2)3 mm
minimum clearance value - non-homogenous field (III/2)3 mm
minimum clearance value - non-homogenous field (III/3)3 mm
Glow wire flammability index GWFI according to EN 60695-2-12850
Glow wire ignition temperature GWIT according to EN 60695-2-13775
Temperature for the ball pressure test according to EN 60695-10-2125 °C

Product Description