| Parameter | Value |
|---|---|
| Step | 5 mm |
| Width [w] | 35 mm |
| Height [h] | 11.8 mm |
| Length [l] | 12 mm |
| Pin Design | Linear Pin Arrangement |
| Observation | WEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Construction | Standard |
| Product Line | COMBICON Connectors M |
| Product Type | Printed circuit board base housing |
| Hole diameter | 1.4 mm |
| Article Review | 01 |
| Number of rows | 1 |
| Overall Height | 8.57 mm |
| Product Family | BCH-HF |
| Clamping flange | Overhead clamping (thread) |
| Color (Housing) | off-white green (6019) |
| Number of poles | 5 |
| Contact material | Cu Alloy |
| Dimension Scheme | |
| Type of mounting | Wave soldering |
| Temple Dimensions | 1 x 1 mm |
| Tightening torque | 0.3 Nm |
| Type of packaging | Boxed Packaging |
| Nominal Current IN | 12 A |
| Nominal voltage UN | 320 V |
| Test Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulating material | PA |
| Weld Pin Length [P] | 3.23 mm |
| Number of potentials | 5 |
| Number of connections | 5 |
| Nominal voltage (II/2) | 400 V |
| Sizing voltage (III/3) | 250 V |
| Surface Characteristics | Galvanically tinned |
| Insulating material group | I |
| CTI according to IEC 60112 | 600 |
| Dimensioning voltage (III/2) | 320 V |
| Ambient Temperature (Service) | -40 °C ... 100 °C (depending on the rating curve) |
| Ambient Temperature (Mounting) | -5 °C ... 100 °C |
| Nominal transient voltage (II/2) | 4 kV |
| Sizing Insulation Voltage (II/2) | 400 V |
| Nominal transient voltage (III/2) | 4 kV |
| Nominal transient voltage (III/3) | 4 kV |
| Sizing Insulation Voltage (III/2) | 320 V |
| Sizing Insulation Voltage (III/3) | 250 V |
| Minimum creepage line value (II/2) | 3 mm |
| Metal surface weld area (top layer) | Tin (4 - 8 μm Sn) |
| Minimum creepage line value (III/2) | 3 mm |
| Minimum creepage line value (III/3) | 3.2 mm |
| Number of Solder Pins Per Potential | 1 |
| Observation regarding the operation | According to DIN EN 61984, COMBICON connectors are connectors without switching power (COC). In the event of use as prescribed, they must not be plugged in or unplugged under voltage or under load. |
| Dimensioning transient voltage (II/2) | 4 kV |
| Flammability class according to UL 94 | V0 |
| Dimensioning Transient Voltage (III/2) | 4 kV |
| Dimensioning transient voltage (III/3) | 4 kV |
| Metal surface contact area (top layer) | Tin (4 - 8 μm Sn) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Metal Surface Contact Area (Middle Layer) | Nickel (1.5 - 4 μm Ni) |
| Metal Surface Welding Area (Middle Layer) | Nickel (1.5 - 4 μm Ni) |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ball hardness test temperature according to EN 60695-10-2 | 125 °C |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | CTI 600 |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2) | 3 mm |
| Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2) | 3 mm |
| minimum value of air insulation distance - non-homogeneous field (III/3) | 3 mm |
| Flammability number of GWFI incandescent filaments according to EN 60695-2-12 | 850 |
| Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13 | 775 |
Technical specifications and performance data