| Parameter | Value |
|---|---|
| GTIN | 4046356959391 |
| Note | Made to Order (non-returnable) |
| Orderkey | 5453897 |
| Packing unit | 100 pc |
| Country of origin | CN (China) |
| Custom tariff number | 85369010 |
| Minimum order quantity | 2000 pc |
| Screw thread (Dimensions) | M3 |
| Pitch (Key Commercial Data) | 5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 9.97 mm |
| Stripping length (Dimensions) | 6 mm |
| Range of articles (Dimensions) | BC-X10 |
| Nominal current IN (Dimensions) | 13.5 A |
| Solder pin surface (Dimensions) | |
| Number of positions (Dimensions) | 9 |
| Dimension a (Key Commercial Data) | 40 mm |
| Rated voltage (II/2) (Dimensions) | 630 V |
| Width [ w ] (Key Commercial Data) | 44.95 mm |
| Height [ h ] (Key Commercial Data) | 13.47 mm |
| Length [ l ] (Key Commercial Data) | 8.15 mm |
| Nominal cross section (Dimensions) | 1.5 mm² |
| Rated voltage (III/2) (Dimensions) | 400 V |
| Rated voltage (III/3) (Dimensions) | 250 V |
| Tightening torque max (Dimensions) | 0.6 Nm |
| Hole diameter (Key Commercial Data) | 1.3 mm |
| Tightening torque, min (Dimensions) | 0.5 Nm |
| Solder pin [P] (Key Commercial Data) | 3.5 mm |
| Weight per Piece (excluding packing) | 7.880 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Internal cylindrical gage (Dimensions) | A1 |
| Rated surge voltage (II/2) (Dimensions) | 4 kV |
| Rated surge voltage (III/2) (Dimensions) | 4 kV |
| Rated surge voltage (III/3) (Dimensions) | 4 kV |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 26 |
| Connection in acc. with standard (Dimensions) | EN-VDE |
| Connection in acc. with standard (Connection data) | EN-VDE |
| 2 conductors with same cross section, solid max. (General) | 0.75 mm² |
| 2 conductors with same cross section, solid min. (General) | 0.14 mm² |
| 2 conductors with same cross section, stranded max. (General) | 0.75 mm² |
| 2 conductors with same cross section, stranded min. (General) | 0.14 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. (General) | 0.5 mm² |
| 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. (General) | 0.25 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (General) | 0.75 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (General) | 0.5 mm² |
Technical specifications and performance data