| Parameter | Value |
|---|---|
| 1 Byte (PROFIBUS) | |
| Link | Card Edge Connectors |
| type | modularity |
| Depth | 62 mm |
| Input | max. 120 W (of which 1.06 W internal losses) |
| width | 14.9 mm |
| height | 62.2 mm |
| Link naming | Outskirts |
| Product Type | I/O Components |
| Mounting type | Slot Smart Element |
| Product Family | Axioline Smart Elements |
| Security class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Stripping length | 8 mm |
| Protection Circuit | Prot. against overvoltages; See the system where you are using the Smart Element. |
| Transmission speed | See the system where you are using the Smart Element. |
| Current consumption | max. 4 A |
| Degree of pollution | 2 (IEC 60664-1, EN 60664-1) |
| Dimensioned Drawing | |
| Input address range | 0 Bytes (all systems except PROFIBUS) |
| Degree of protection | Ip20 |
| Number of interfaces | 1 |
| Output address range | 0 Bytes |
| Overvoltage Category | II (IEC 60664-1, EN 60664-1) |
| Power supply voltage | via Card Edge connectors |
| Process data channel | 0 Bit |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| ID code (hexadecimal) | none |
| Installation Location | See the system where you are using the Smart Element. |
| Need configuration data | 6 Bytes |
| Note on connection type | Observe the information on the conductor cross-sections in the "Axioline Smart Element" user manual. |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m a.s.l.) |
| AWG conductor cross-section | 24 ... 16 |
| Conductor cross-section AWG | 24 ... 16 |
| Rigid conductor cross-section | 0.25 mm² ... 1.5 mm² |
| Need for parameterization data | 1 Byte |
| Ambient temperature (operating) | -25 °C ... 60 °C |
| Flexible conductor cross-section | 0.25 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Air pressure (transport and storage) | 70 kPa ... 106 kPa (up to 3000 m a.s.l.) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Test voltage: Logic power supply / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V power supply (periphery) / Functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: Logic power supply / 24V power supply (periphery) | 500 V AC, 50 Hz, 1 min. |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 1.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 1.5 mm² |
Technical specifications and performance data