Service time: Monday to Friday 9:00-18:00
AXL F SSI1 AO1 1H - AXL F SSI1 AO1 1H 2688433 PHOENIX CONTACT Special function module
In Stock Hot Product

AXL F SSI1 AO1 1H

AXL F SSI1 AO1 1H 2688433 PHOENIX CONTACT Special function module

$0.00USD
4429 in stock
Key Specifications
GTIN:4046356644952
Note:Made to Order (non-returnable)
Orderkey:2688433
Catalog page:Page 122 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356644952
NoteMade to Order (non-returnable)
Orderkey2688433
Catalog pagePage 122 (C-6-2017)
Packing unit1 pc
(Interfaces)Transient protection
(Encoder data)-10 V ... 10 V
(Analog outputs)Analog I/O 500 V AC 50 Hz 1 min.
(Encoder inputs)Transient protection
Country of originDE (Germany)
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)Supply voltage input UI
Precision (Encoder data)typ. 0.1 % (of output range final value)
No. of channels (General)2
Output name (Encoder data)Analog outputs
Connection method (General)Bus base module
Data formats (Encoder data)IB IL, S7-compatible, standardized representation
Depth (Key Commercial Data)54 mm
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)126.1 mm
Net weight (Connection data)135 g
Parity (Axioline potentials)Even, odd or no parity
Transmission speed (General)100 Mbps
D/A resolution (Encoder data)16 bit
Test section (Analog outputs)Logic 500 V AC 50 Hz 1 min.
Power consumption (Interfaces)max. 1.4 W (Supply of the SSI interface and the analog output (20 mA), without sensor supply)
Voltage range (Encoder inputs)19.5 V DC ... 30 V DC (including all tolerances, including ripple)
Mounting type (Connection data)DIN rail
Type of protection (Interfaces)Surge protection of the supply voltage
Connection method (Encoder data)Push-in connection
Current consumption (Interfaces)max. 60 mA (Supply of the SSI interface and the analog output (20 mA), without sensor supply)
Designation (Ambient conditions)Axioline F connector
Input name (Axioline potentials)SSI interface
Number of outputs (Encoder data)1
Degree of protection (Dimensions)IP20
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC including all tolerances, including ripple
Type of protection (Encoder data)Surge protection
D/A conversion time (Encoder data)5 µs
Type of protection (Encoder inputs)Surge protection
Connection technology (Encoder data)2-wire (shielded, twisted pair)
Current output signal (Encoder data)0 mA ... 20 mA
Voltage output signal (Encoder data)0 V ... 5 V
Weight per Piece (excluding packing)135.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Encoder signals (Axioline potentials)Single-turn and multi-turn encoder, length measuring sticks
Input frequency (Axioline potentials)to 2 MHz (Can be parameterized: 67.5 kHz, 125 kHz (default), 250 kHz, 500 kHz, 1 MHz, 2 MHz)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
Number of inputs (Axioline potentials)1
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Connection method (Axioline potentials)Push-in connection
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (Encoder inputs)24 V DC (UI- 0.5 V)
Permissible cable length (Encoder data)max. 250 m
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Dimensional drawing (Key Commercial Data)
Current carrying capacity (Encoder inputs)max. 500 mA
Adjustable resolution (Axioline potentials)8 ... 56 bit
Protective circuit/component (Encoder data)Electronic (35 V, permanent)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Encoder supply voltage (Axioline potentials)24 V DC (UI- 0.5 V)
Measured value representation (Encoder data)16 bits
Transmission frequency (Axioline potentials)2 MHz
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Description of the input (Axioline potentials)RS-422 interface according to SSI specification
Load/output load current output (Encoder data)max. 500 Ω
Load/output load voltage output (Encoder data)> 2 kΩ
Representation of output values (Encoder data)16 bits (15 bits + sign)
Note on weight specifications (Connection data)with connectors and bus base module
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²

Product Description

AxiolineF special function module, 1SSI interface for absolute value transmitter, 1 analog output: 0-10V, ±10V, 0-5V, ±5V, 0-20mA, 4-20mA, ±20mA, 2-conductor connection technology (including bus base
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide