Service time: Monday to Friday 9:00-18:00
AXL F SGI2 1H - AXL F SGI2 1H 2702911 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F SGI2 1H

AXL F SGI2 1H 2702911 PHOENIX CONTACT I/O module

$0.00USD
4178 in stock
Key Specifications
GTIN:4055626459288
Orderkey:2702911
Packing unit:1 pc
(Interfaces):Polarity reversal protection of the supply voltage
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626459288
Orderkey2702911
Packing unit1 pc
(Interfaces)Polarity reversal protection of the supply voltage
(Analog outputs)Functional earth ground 500 V AC 50 Hz 1 min.
Country of originDE (Germany)
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)Supply for analog modules (UA)
Impedance (Analog inputs)> 43 Ω (per channel)
No. of channels (General)2
Characteristics (Contacts)can be parameterized: 350 μV/V ... 6500 μV/V
Connection method (General)Bus base module
Depth (Key Commercial Data)54 mm
Number of inputs (Contacts)2
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Bridge voltage U0 (Contacts)5 V
Height (Key Commercial Data)126.1 mm
Transmission speed (General)100 Mbps
Test section (Analog outputs)Logic 500 V AC 50 Hz 1 min.
Output current (Analog inputs)max. 115 mA (per channel)
Output voltage (Analog inputs)typ. 5 V
Power consumption (Interfaces)typ. 2.6 W (with maximum load: 8 weighing cells with 350 Ω per channel)
Quantity (Axioline potentials)2 (Ka1-Kb1, Ka2-Kb2)
Bridge difference Ud (Contacts)Measuring range specified by selecting the characteristic
Net weight (Ambient conditions)187.7 g
Type of protection (Interfaces)Surge protection of the supply voltage
Connection technology (Contacts)6 or 4-wire, twisted pair shielded cable
Current consumption (Interfaces)typ. 25 mA (with typical load: 1 weighing cell with 350 Ω, only one channel loaded)
Degree of protection (Dimensions)IP20
Description (Axioline potentials)Floating N/O contact
Number of outputs (Analog inputs)2
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Mounting type (Ambient conditions)DIN rail
Output description (Analog inputs)Jumper supply
Description of the input (Contacts)Input channels for strain gauge
Operating mode (Ambient conditions)Process data mode with 6 words
Weight per Piece (excluding packing)187.700 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Contact resistance (Axioline potentials)< 1 Ω (typical)
Measured value representation (Contacts)32 bits
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Dimensional drawing (Key Commercial Data)
Typical response time (Axioline potentials)typ. 0.2 ms (opening)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Note on weight specifications (Ambient conditions)with connectors and bus base module
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)

Product Description

AxiolineF, Extensometer logging module, transmission rate on local bus: 100 MBit/s, protection rating: IP20, including bus socket module and AxiolineF connectors
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top