Key Specifications
GTIN:4046356730518
Note:Made to Order (non-returnable)
Orderkey:2701230
Catalog page:Page 109 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356730518
NoteMade to Order (non-returnable)
Orderkey2701230
Catalog pagePage 109 (C-6-2017)
Depth (Note)54 mm
Packing unit1 pc
Width (Note)53.6 mm
(Dimensions)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
(Interfaces)max. 16 A (as of HW 02, protection against polarity reversal up to 5 A)
Height (Note)126.1 mm
Caption (Note)Dimensions
Country of originDE (Germany)
(Digital outputs)24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection (Interfaces)max. 8 A (up to HW 01, protection against polarity reversal up to 5 A)
Designation (Interfaces)Supply for digital output modules (UO)
No. of channels (General)2
Note on dimensions (Note)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Dimensional drawing (Note)
Connection method (General)Bus base module
Supply voltage (Interfaces)24 V DC
(Standards and Regulations)No hazardous substances above threshold values
Net weight (Connection data)240 g
Transmission speed (General)100 Mbps
Power consumption (Interfaces)max. 240 W (up to HW 01, of which 1.5 W constitute internal losses)
Test section (Digital outputs)5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
Mounting type (Connection data)DIN rail
Type of protection (Interfaces)Surge protection of the supply voltage
Current consumption (Interfaces)max. 8 A (up to HW 01, fuse externally)
Designation (Ambient conditions)Axioline F connector
Degree of protection (Dimensions)IP20
Output name (Axioline potentials)Digital outputs
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Output voltage (Axioline potentials)24 V
Weight per Piece (excluding packing)240.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Connection method (Axioline potentials)Push-in connection
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Number of outputs (Axioline potentials)32
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, lamp (Axioline potentials)max. 12 W (at nominal voltage)
Type of protection (Axioline potentials)Short-circuit protection, overload protection of the outputs
Nominal load, ohmic (Axioline potentials)max. 12 W (48 Ω, with nominal voltage)
Connection technology (Axioline potentials)1-wire
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C (Standard)
Nominal output voltage (Axioline potentials)24 V DC
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Nominal load, inductive (Axioline potentials)max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Note on weight specifications (Connection data)with connectors and bus base module
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Maximum output current per module (Axioline potentials)8 A (up to HW 01, fuse externally)
Maximum output current per channel (Axioline potentials)500 mA
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²

Product Description

AxiolineF, Digital output module, Digital outputs:32, 24 VDC, 500 mA, connection technology:1 conductor, Extreme Condition variant, transmission speed on the local bus:100 MBit/s, protection index: IP
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual