Service time: Monday to Friday 9:00-18:00
AXL F DO16/1 1H - AXL F DO16/1 1H 2688349 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F DO16/1 1H

AXL F DO16/1 1H 2688349 PHOENIX CONTACT I/O module

$0.00USD
4233 in stock
Key Specifications
GTIN:4046356606530
Orderkey:2688349
Catalog page:Page 109 (C-6-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356606530
Orderkey2688349
Catalog pagePage 109 (C-6-2017)
Packing unit1 pc
(Interfaces)Polarity reversal protection of the supply voltage
Country of originDE (Germany)
(Digital outputs)24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection (Interfaces)max. 8 A (polarity reversal protection up to 5 A)
Designation (Interfaces)Supply for digital output modules (UO)
No. of channels (General)2
Connection method (General)Bus base module
Depth (Key Commercial Data)54 mm
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)126.1 mm
Net weight (Connection data)134 g
Transmission speed (General)100 Mbps
Power consumption (Interfaces)max. 240 W (of which 560 mW with internal losses)
Test section (Digital outputs)5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
Mounting type (Connection data)DIN rail
Type of protection (Interfaces)Surge protection of the supply voltage
Current consumption (Interfaces)max. 8 A (provide external protection)
Designation (Ambient conditions)Axioline F connector
Degree of protection (Dimensions)IP20
Output name (Axioline potentials)Digital outputs
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Output voltage (Axioline potentials)24 V
Weight per Piece (excluding packing)134.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Connection method (Axioline potentials)Push-in connection
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Number of outputs (Axioline potentials)16
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, lamp (Axioline potentials)max. 12 W (at nominal voltage)
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Type of protection (Axioline potentials)Short-circuit protection, overload protection of the outputs
Dimensional drawing (Key Commercial Data)
Nominal load, ohmic (Axioline potentials)max. 12 W (48 Ω, with nominal voltage)
Connection technology (Axioline potentials)1-wire
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Nominal output voltage (Axioline potentials)24 V DC
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Nominal load, inductive (Axioline potentials)max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Note on weight specifications (Connection data)with connectors and bus base module
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Maximum output current per module (Axioline potentials)8 A (provide external protection)
Maximum output current per channel (Axioline potentials)500 mA
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²

Product Description

AxiolineF, Digital output module, Digital outputs:16, 24 VDC, 500 mA, connection technology:1 driver, transmission speed on the local bus:100 MBit/s, protection index: IP20, including bus socket modul
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top