Service time: Monday to Friday 9:00-18:00
AXL F DI8/2 48/60DC 1F - AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F DI8/2 48/60DC 1F

AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module

$0.00USD
4512 in stock
Key Specifications
:60 V (Nominal voltage)
Type:block modular
Depth:54 mm
Width:53.6 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
60 V (Nominal voltage)
Typeblock modular
Depth54 mm
Width53.6 mm
Height126.1 mm
Input nameDigital inputs
Current drawmax. 120 mA
Product typeI/O component
Input voltage48 V (Nominal voltage)
Mounting typeDIN rail mounting
Product familyAxioline F
Supply voltage5 V DC (via bus base module)
Connection nameAxioline F connector
Article revision01
Number of inputs8
Pollution degree2
Stripping length8 mm
Connection methodBus base module
Input filter time< 1 ms
Mounting positionany (no temperature derating)Nominal mounting position: wall mounting on horizontal DIN rail
Scope of deliveryincluding bus base module and Axioline F connectors
Input address area1 Byte
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Protective circuitPolarity reversal protection of the inputs
Special propertiescorresponds to standard IEC 61850-3
Transmission speed100 Mbps
Dimensional drawing
Input voltage range-100 V DC ... 100 V DC
Note on applicationOnly for industrial use
Output address area0 Byte
Degree of protectionIP20
Number of interfaces2
Overvoltage categoryIII (EN 61010-2-201/IEC 61010-2-201)
Standard designationAmbient conditions
Connection technology2-conductor
Required parameter data3 Byte
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Description of the inputEN 61131-2 type 1
Standards/specificationsIEC 61850-3
Nominal input voltage UIN48 V DC
Test voltage: I/Os / logic4 kV
Conductor cross section AWG24 ... 16
Required configuration data6 Byte
Nominal input current at UIN2.5 mA
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Input voltage range "0" signal-12 V DC ... 12 V DC
Input voltage range "1" signal32 V DC ... 100 V DC
Ambient temperature (operation)-25 °C ... 60 °C
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Test voltage: I/O/functional ground4 kV
Test voltage: Logic/functional ground1 kV
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Test voltage: I/O / I/O (adjacent connectors)2.5 kV
Maximum power dissipation for nominal condition1.8 W

Product Description

AxiolineF, Digital input module, Digital inputs: 8, 48 VDC / 60 VDC, connection technology: 2 conductors, corresponds to IEC 61850-3 standard, transmission speed on the local bus:100 MBit/s, protectio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top