| Parameter | Value |
|---|---|
| 60 V (Nominal voltage) | |
| Type | block modular |
| Depth | 54 mm |
| Width | 53.6 mm |
| Height | 126.1 mm |
| Input name | Digital inputs |
| Current draw | max. 120 mA |
| Product type | I/O component |
| Input voltage | 48 V (Nominal voltage) |
| Mounting type | DIN rail mounting |
| Product family | Axioline F |
| Supply voltage | 5 V DC (via bus base module) |
| Connection name | Axioline F connector |
| Article revision | 01 |
| Number of inputs | 8 |
| Pollution degree | 2 |
| Stripping length | 8 mm |
| Connection method | Bus base module |
| Input filter time | < 1 ms |
| Mounting position | any (no temperature derating)Nominal mounting position: wall mounting on horizontal DIN rail |
| Scope of delivery | including bus base module and Axioline F connectors |
| Input address area | 1 Byte |
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Protective circuit | Polarity reversal protection of the inputs |
| Special properties | corresponds to standard IEC 61850-3 |
| Transmission speed | 100 Mbps |
| Dimensional drawing | |
| Input voltage range | -100 V DC ... 100 V DC |
| Note on application | Only for industrial use |
| Output address area | 0 Byte |
| Degree of protection | IP20 |
| Number of interfaces | 2 |
| Overvoltage category | III (EN 61010-2-201/IEC 61010-2-201) |
| Standard designation | Ambient conditions |
| Connection technology | 2-conductor |
| Required parameter data | 3 Byte |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Description of the input | EN 61131-2 type 1 |
| Standards/specifications | IEC 61850-3 |
| Nominal input voltage UIN | 48 V DC |
| Test voltage: I/Os / logic | 4 kV |
| Conductor cross section AWG | 24 ... 16 |
| Required configuration data | 6 Byte |
| Nominal input current at UIN | 2.5 mA |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Input voltage range "0" signal | -12 V DC ... 12 V DC |
| Input voltage range "1" signal | 32 V DC ... 100 V DC |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Test voltage: I/O/functional ground | 4 kV |
| Test voltage: Logic/functional ground | 1 kV |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Test voltage: I/O / I/O (adjacent connectors) | 2.5 kV |
| Maximum power dissipation for nominal condition | 1.8 W |