Service time: Monday to Friday 9:00-18:00
AXL F DI16/1 DO8/2-2A 2H - AXL F DI16/1 DO8/2-2A 2H 2702291 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F DI16/1 DO8/2-2A 2H

AXL F DI16/1 DO8/2-2A 2H 2702291 PHOENIX CONTACT I/O module

$0.00USD
4412 in stock
Key Specifications
GTIN:4055626071848
Orderkey:2702291
Catalog page:Page 113 (C-6-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626071848
Orderkey2702291
Catalog pagePage 113 (C-6-2017)
Packing unit1 pc
(Interfaces)Polarity reversal protection of the supply voltage
Country of originDE (Germany)
(Connection data)Short-circuit / overload of the digital outputs Yes
(Digital outputs)24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection (Interfaces)max. 16 A (polarity reversal protection up to 5 A)
Designation (Interfaces)Supply for digital input and output modules (UIO)
No. of channels (General)2
Connection method (General)Bus base module
Depth (Key Commercial Data)54 mm
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)129.9 mm
Net weight (Connection data)111 g
Output name (Digital inputs)Digital outputs
Transmission speed (General)100 Mbps
Power consumption (Interfaces)max. 480 W (of which 6.4 W internal losses)
Test section (Digital outputs)5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
Mounting type (Connection data)DIN rail
Output voltage (Digital inputs)24 V DC
Type of protection (Interfaces)Surge protection of the supply voltage
Current consumption (Interfaces)max. 16 A (Provide external protection; if the total current of 8 A is exceeded, connect the supply at the power connector parallel via both terminal points.)
Designation (Ambient conditions)Axioline F connectors (digital inputs)
Input name (Axioline potentials)Digital inputs
Degree of protection (Dimensions)IP20
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Connection method (Digital inputs)Push-in connection
Number of outputs (Digital inputs)8
Nominal load, lamp (Digital inputs)max. 48 W (at nominal voltage)
Type of protection (Digital inputs)Short-circuit protection, overload protection of the outputs
Nominal load, ohmic (Digital inputs)max. 48 W (12 Ω, at nominal load)
Weight per Piece (excluding packing)111.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
Connection technology (Digital inputs)2-wire
Diagnostics messages (Connection data)I/O supply failure Yes
Number of inputs (Axioline potentials)16
Connection method (Axioline potentials)Push-in connection
Input filter time (Axioline potentials)3000 µs (default)
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (Digital inputs)24 V DC
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, inductive (Digital inputs)max. 48 VA (1.2 H, 12 Ω, at nominal load)
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Type of protection (Axioline potentials)Polarity reversal protection of the inputs
Dimensional drawing (Key Commercial Data)
Connection technology (Axioline potentials)1-wire
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Description of the input (Axioline potentials)EN 61131-2 types 1 and 3
Note on weight specifications (Connection data)with connectors and bus base module
Maximum output current per module (Digital inputs)16 A (provide external protection)
Nominal input current at UIN (Axioline potentials)2.4 mA
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Maximum output current per channel (Digital inputs)2 A
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Input voltage range "0" signal (Axioline potentials)-3 V DC ... 5 V DC
Input voltage range "1" signal (Axioline potentials)11 V DC ... 30 V DC
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²

Product Description

AxiolineF, Digital input/output module, Digital inputs: 16, 24 VDC, connection technology: 1 driver, Digital outputs:8, 24 VDC, 2 A, connection technology:2 drivers, transmission speed on the local bu
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top