Key Specifications
GTIN:4046356606455
Orderkey:2688310
Catalog page:Page 106 (C-6-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356606455
Orderkey2688310
Catalog pagePage 106 (C-6-2017)
Packing unit1 pc
(Interfaces)Polarity reversal protection of the supply voltage
(Digital inputs)24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Country of originDE (Germany)
Custom tariff number85389091
Designation (General)Axioline F local bus
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection (Interfaces)max. 8 A (polarity reversal protection up to 5 A)
Designation (Interfaces)Supply for digital input modules (UI)
No. of channels (General)2
Connection method (General)Bus base module
Depth (Key Commercial Data)54 mm
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Height (Key Commercial Data)126.1 mm
Net weight (Connection data)185.5 g
Transmission speed (General)100 Mbps
Test section (Digital inputs)5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
Power consumption (Interfaces)max. 480 mW
Mounting type (Connection data)DIN rail
Type of protection (Interfaces)Surge protection of the supply voltage
Current consumption (Interfaces)max. 20 mA
Designation (Ambient conditions)Axioline F connector
Input name (Axioline potentials)Digital inputs
Degree of protection (Dimensions)IP20
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Weight per Piece (excluding packing)185.500 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Stripping length (Ambient conditions)8 mm
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
Number of inputs (Axioline potentials)16
REACh SVHC (Standards and Regulations)Lead 7439-92-1
Connection method (Axioline potentials)Push-in connection
Input filter time (Axioline potentials)3000 µs (default)
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Type of protection (Axioline potentials)Polarity reversal protection of the inputs
Dimensional drawing (Key Commercial Data)
Connection technology (Axioline potentials)1-wire
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Description of the input (Axioline potentials)EN 61131-2 types 1 and 3
Note on weight specifications (Connection data)with connectors and bus base module
Nominal input current at UIN (Axioline potentials)2.4 mA
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Input voltage range "0" signal (Axioline potentials)-3 V DC ... 5 V DC
Input voltage range "1" signal (Axioline potentials)11 V DC ... 30 V DC
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²

Product Description

AxiolineF, Digital input module, Digital inputs: 16, 24 VDC, connection technology: 1 driver, transmission speed on the local bus:100 MBit/s, protection index: IP20, including bus socket module and Ax
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top