

| Parameter | Value |
|---|---|
| GTIN | 4046356730082 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2701239 |
| Catalog page | Page 121 (C-6-2017) |
| Depth (Note) | 54 mm |
| Packing unit | 1 pc |
| Width (Note) | 53.6 mm |
| (Dimensions) | -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) |
| (Interfaces) | Polarity reversal protection of the supply voltage |
| Height (Note) | 126.1 mm |
| (Encoder inputs) | max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware) |
| Country of origin | DE (Germany) |
| (Digital outputs) | Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g |
| Custom tariff number | 85389091 |
| (Ambient conditions) | Error at the symmetrical incremental encoder Yes |
| Designation (General) | Axioline F local bus |
| (Axioline potentials) | max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware) |
| Protection (Interfaces) | max. 8 A (polarity reversal protection up to 5 A) |
| Designation (Interfaces) | Supply voltage input UI |
| Input name (Encoder data) | Digital inputs |
| No. of channels (General) | 2 |
| Note on dimensions (Note) | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
| Dimensional drawing (Note) | |
| Connection method (General) | Bus base module |
| Input name (Counter inputs) | Incremental encoder inputs |
| Supply voltage (Interfaces) | 24 V DC |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Designation (Encoder inputs) | Asymmetrical incremental encoders |
| Output name (Digital inputs) | Digital outputs |
| Transmission speed (General) | 100 Mbps |
| Cable length (Counter inputs) | 30 m |
| Power consumption (Interfaces) | max. 60 W (of which 1.6 W internal losses) |
| Voltage range (Encoder inputs) | 19.2 V DC ... 30 V DC |
| Net weight (Ambient conditions) | 233.9 g |
| Number of inputs (Encoder data) | 8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2) |
| Output voltage (Digital inputs) | 24 V DC |
| Type of protection (Interfaces) | Surge protection of the supply voltage |
| Connection method (Encoder data) | Push-in connection |
| Current consumption (Interfaces) | max. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.) |
| Encoder signals (Counter inputs) | Symmetrical and asymmetrical encoders |
| Input frequency (Encoder inputs) | max. 300 kHz (1 channel wired) |
| Input name (Axioline potentials) | Counter input for 24 V signals |
| Resolution (Axioline potentials) | 32 bits |
| Degree of protection (Dimensions) | IP20 |
| Number of inputs (Counter inputs) | 2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2) |
| Supply voltage range (Interfaces) | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
| Connection method (Counter inputs) | Push-in connection |
| Connection method (Digital inputs) | Push-in connection |
| Mechanical tests (Digital outputs) | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Mounting type (Ambient conditions) | DIN rail |
| Number of outputs (Digital inputs) | 2 (Out1, Out2) |
| Protection class (Digital outputs) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Input current (Axioline potentials) | 2.5 mA (per channel) |
| Input voltage (Axioline potentials) | 24 V DC |
| Nominal load, lamp (Digital inputs) | max. 12 W (at nominal voltage) |
| Type of protection (Digital inputs) | Short-circuit protection, overload protection of the outputs |
| Type of protection (Encoder inputs) | Short-circuit protection |
| Connection technology (Encoder data) | 1-wire (optionally 2, 3-wire) |
| Nominal load, ohmic (Digital inputs) | max. 12 W (48 Ω, with nominal voltage) |
| Weight per Piece (excluding packing) | 233.900 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Input frequency (Axioline potentials) | max. 300 kHz (1 channel wired) |
| Signal voltage level (Encoder inputs) | Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Connection technology (Digital inputs) | 1-wire |
| Number of inputs (Axioline potentials) | 2 (S1, S2) |
| Connection method (Axioline potentials) | Push-in connection |
| Description of the input (Encoder data) | EN 61131-2, type 3 |
| Encoder supply voltage (Encoder inputs) | 5 V DC |
| Nominal output voltage (Digital inputs) | 24 V DC |
| Nominal output voltage (Encoder inputs) | 24 V DC |
| Nominal load, inductive (Digital inputs) | max. 12 VA (1.2 H, 48 Ω, with nominal voltage) |
| Diagnostics messages (Ambient conditions) | Short-circuit / overload of the digital outputs Yes |
| Current carrying capacity (Encoder inputs) | typ. 500 mA |
| Nominal input current at UIN (Encoder data) | 2.5 mA (per channel) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C (Standard) |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Input voltage range "0" signal (Encoder data) | -3 V DC ... 5 V DC |
| Input voltage range "1" signal (Encoder data) | 11 V DC ... 30 V DC |
| Permissible humidity (operation) (Dimensions) | 5 % ... 95 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Description of the input (Axioline potentials) | EN 61131-2, type 3 |
| Type of connection of signals (Encoder inputs) | Push-in connection |
| Number of 5 V encoder supplies (Encoder inputs) | 2 (UE1, UE2) |
| Number of 24 V encoder supplies (Encoder inputs) | 2 (US1, US2) |
| Note on weight specifications (Ambient conditions) | with connectors and bus base module |
| Maximum output current per channel (Digital inputs) | 500 mA |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Encoder types that can be connected (Encoder inputs) | max. 2 (A, B, (Z)) |
| Input voltage range "0" signal (Axioline potentials) | -3 V DC ... 5 V DC |
| Input voltage range "1" signal (Axioline potentials) | 11 V DC ... 30 V DC |
| Permissible humidity (storage/transport) (Dimensions) | 5 % ... 95 % (non-condensing) |
| Common mode voltage range signal - ground (Encoder inputs) | -10 V ... 13.2 V |
| Permissible cable length to the sensor (Axioline potentials) | 30 m |
Technical specifications and performance data
Installation and operation guide