Service time: Monday to Friday 9:00-18:00
AXL F AI2 AO2 XC 1H - AXL F AI2 AO2 XC 1H 1035429 PHOENIX CONTACT I/O module
In Stock Hot Product

AXL F AI2 AO2 XC 1H

AXL F AI2 AO2 XC 1H 1035429 PHOENIX CONTACT I/O module

$0.00USD
3260 in stock
Key Specifications
GTIN:4055626541792
Note:Made to Order (non-returnable)
Orderkey:1035429
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626541792
NoteMade to Order (non-returnable)
Orderkey1035429
Packing unit1 pc
(Dimensions)-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
(Interfaces)Transient protection supply voltage
(Analog inputs)-10 V ... 10 V
(Analog outputs)Analog inputs and outputs/functional earth ground 500 V AC 50 Hz 1 min.
Country of originDE (Germany)
Custom tariff number85389091
Designation (General)Axioline F local bus
(Axioline potentials)-10 V ... 10 V
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)Supply for analog modules (UA)
No. of channels (General)2
Precision (Analog inputs)typ. 0.1 % (of output range final value)
Connection method (General)Bus base module
Depth (Key Commercial Data)54 mm
Output name (Analog inputs)Analog outputs
Supply voltage (Interfaces)24 V DC
Width (Key Commercial Data)35 mm
(Standards and Regulations)No hazardous substances above threshold values
Data formats (Analog inputs)IB IL, S7-compatible, standardized representation
Height (Key Commercial Data)126.1 mm
Net weight (Connection data)197 g
Transmission speed (General)100 Mbps
Caption (Key Commercial Data)Dimensional drawing
Test section (Analog outputs)5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
D/A resolution (Analog inputs)16 bit
Power consumption (Interfaces)max. 1.92 W
Mounting type (Connection data)DIN rail
Type of protection (Interfaces)Surge protection of the supply voltage
Current consumption (Interfaces)typ. 40 mA
Designation (Ambient conditions)Axioline F connector
Input name (Axioline potentials)Analog inputs
Connection method (Analog inputs)Push-in connection
Degree of protection (Dimensions)IP20
Number of outputs (Analog inputs)2
Supply voltage range (Interfaces)19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Data formats (Axioline potentials)IB IL, S7-compatible, standardized representation
Input filter (Axioline potentials)30 Hz, 12 kHz and mean-value generation (can be parameterized)
Type of protection (Analog inputs)Short-circuit and overload protection
Process data update (Analog inputs)150 µs
Resolution A/D (Axioline potentials)16 bit
Weight per Piece (excluding packing)197.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection technology (Analog inputs)2-wire
Current output signal (Analog inputs)0 mA ... 20 mA
Stripping length (Ambient conditions)8 mm
Voltage output signal (Analog inputs)0 V ... 5 V
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Connection method (Ambient conditions)Push-in connection
Number of inputs (Axioline potentials)2
Connection method (Axioline potentials)Push-in connection
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Note on dimensions (Key Commercial Data)The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
Type of protection (Axioline potentials)Transient protection of inputs
A/D conversion time (Axioline potentials)2 µs
Dimensional drawing (Key Commercial Data)
Current input signal (Axioline potentials)0 mA ... 20 mA
Voltage input signal (Axioline potentials)0 V ... 5 V
Connection technology (Axioline potentials)2-wire
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C (Standard)
Limit frequency (3 dB) (Axioline potentials)30 Hz
Protective circuit/component (Analog inputs)electronic
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (non-condensing)
Description of the input (Axioline potentials)Differential inputs, voltage or current can be chosen separately
Load/output load current output (Analog inputs)≤ 500 Ω
Load/output load voltage output (Analog inputs)> 2 kΩ
Note on weight specifications (Connection data)with connectors and bus base module
Representation of output values (Analog inputs)16 bits (15 bits + sign)
Note on the connection method (Ambient conditions)Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Measured value representation (Axioline potentials)16 bits (15 bits + sign bit)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Input resistance current input (Axioline potentials)104 Ω (typical)
Conductor cross section AWG max. (Ambient conditions)16
Conductor cross section AWG min. (Ambient conditions)24
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (non-condensing)
Conductor cross section solid max. (Ambient conditions)1.5 mm²
Conductor cross section solid min. (Ambient conditions)0.2 mm²
Input resistance of voltage input (Axioline potentials)268 kΩ (typical)
Note regarding the connection technology (Analog inputs)shielded, twisted pair
Conductor cross section flexible max. (Ambient conditions)1.5 mm²
Conductor cross section flexible min. (Ambient conditions)0.2 mm²
Note regarding the connection technology (Axioline potentials)shielded, twisted pair
Common mode voltage range signal - ground (Axioline potentials)-50 V DC ... 50 V DC

Product Description

AxiolineF, Analog input/output module, Analog inputs: 2, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, -20 mA... 20 mA, connection technology: 2 conductors, An
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty