Service time: Monday to Friday 9:00-18:00
AXL E S3 DI8 DO4 2A M12 6M - AXL E S3 DI8 DO4 2A M12 6M 2701551 PHOENIX CONTACT Distributed I/O device
In Stock Hot Product

AXL E S3 DI8 DO4 2A M12 6M

AXL E S3 DI8 DO4 2A M12 6M 2701551 PHOENIX CONTACT Distributed I/O device

$0.00USD
3408 in stock
Key Specifications
GTIN:4046356763981
Orderkey:2701551
Catalog page:Page 201 (C-6-2017)
Depth (Note):38 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356763981
Orderkey2701551
Catalog pagePage 201 (C-6-2017)
Depth (Note)38 mm
Packing unit1 pc
Width (Note)60 mm
(Interfaces)FTP
Height (Note)185 mm
Country of originDE (Germany)
(Digital outputs)24 V supply (actuator supply, digital outputs)/FE 500 V AC 50 Hz 1 min.
Input name (Supply)Digital inputs
Custom tariff number85176200
Designation (General)Sercos
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)Sercos
Drill hole spacing (Note)198.5 mm
No. of channels (General)2
Note on dimensions (Note)The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Number of inputs (Supply)8
Connection method (Supply)M12 connector, double occupancy
Dimensional drawing (Note)
Input filter time (Supply)< 1000 µs
Specification (Interfaces)Sercos specification 1.1.2
Connection method (General)M12 fast connection technology
Device profile (Interfaces)FSP_IO
Equipment type (Interfaces)Sercos slave
Type of protection (Supply)Overload protection, short-circuit protection of sensor supply
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Output name (Digital inputs)Digital outputs
Transmission speed (General)100 Mbps (with auto negotiation)
Number of positions (General)4
Connection technology (Supply)4-wire
Test section (Digital outputs)24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
Net weight (Ambient conditions)708.1 g
Output voltage (Digital inputs)24 V
Protocols supported (Interfaces)HTTP
Degree of protection (Dimensions)IP65/IP67
Description of the input (Supply)EN 61131-2 types 1 and 3
Connection method (Digital inputs)M12 connector, (A-coded)
Mounting type (Ambient conditions)Wall mounting or DIN rail mounting; both with mounting plate.
Number of outputs (Digital inputs)4
Type of protection (Digital inputs)Overload protection, short-circuit protection of outputs
Nominal load, ohmic (Digital inputs)48 W (48 Ω, with nominal voltage)
Weight per Piece (excluding packing)708.100 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Housing material (Ambient conditions)Zinc die-cast
Nominal input current at UIN (Supply)typ. 3 mA
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Connection technology (Digital inputs)3-wire
Designation connection point (General)Copper cable
System-specific protocols (Interfaces)Sercos protocols Sercos
Input voltage range "0" signal (Supply)0 V ... 5 V DC
Input voltage range "1" signal (Supply)11 V DC ... 30 V DC
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (Digital inputs)24 V DC (from voltage UA)
Note on the connection method (General)D-coded
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, inductive (Digital inputs)48 VA (1.2 H, 48 Ω, with nominal voltage)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Designation (System limits of the bus coupler)Actuators (UA)
Supply voltage (System limits of the bus coupler)24 V DC
Maximum output current per channel (Digital inputs)2 A
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Connection method (System limits of the bus coupler)M12 connector (T-coded)
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 %
Current consumption (System limits of the bus coupler)typ. 30 mA ±15 % (at 24 V DC)
Number of positions (System limits of the bus coupler)4
Nominal supply voltage range (System limits of the bus coupler)18 V DC ... 31.2 V DC (including all tolerances, including ripple)

Product Description

Axioline E, Digital input/output equipment, Sercos, M12 quick connect technology, Digital inputs: 8, 24 V DC, connection technology: 4 conductors, Digital outputs: 4, 24 V DC, 2 A, connection technolo
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top