Service time: Monday to Friday 9:00-18:00
AXL E PB IOL8 DI4 M12 6M - AXL E PB IOL8 DI4 M12 6M 2701508 PHOENIX CONTACT Distributed I/O device
In Stock Hot Product

AXL E PB IOL8 DI4 M12 6M

AXL E PB IOL8 DI4 M12 6M 2701508 PHOENIX CONTACT Distributed I/O device

$0.00USD
3757 in stock
Key Specifications
GTIN:4046356763608
Orderkey:2701508
(Supply):max. 2 A (at UA(IO-Link B ports, pin 2 and pin 5))
Catalog page:Page 203 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356763608
Orderkey2701508
(Supply)max. 2 A (at UA(IO-Link B ports, pin 2 and pin 5))
Catalog pagePage 203 (C-6-2017)
Depth (Note)38 mm
Packing unit1 pc
Width (Note)60 mm
Height (Note)185 mm
(IO-Link inputs)Short-circuit protection
Country of originDE (Germany)
(Digital outputs)24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min.
Custom tariff number85176200
Designation (General)PROFIBUS DP
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)PROFIBUS DP
Drill hole spacing (Note)198.5 mm
No. of channels (General)2
Note on dimensions (Note)The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Dimensional drawing (Note)
Port type (Digital inputs)Class A
Connection method (General)M12 fast connection technology
Equipment type (Interfaces)PROFIBUS slave
Type of protection (Supply)Overload protection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Transmission speed (General)9.6 kbps ... 12 Mbps (Automatic baud rate detection)
Number of positions (General)5
Signal delay (IO-Link inputs)max. 150 µs (when switched on)
(Supply of the IO-Link ports)Short-circuit protection for the sensor supply
Test section (Digital outputs)24 V supply (communications power and sensor supply, IO-Link ports)/bus connection 500 V AC 50 Hz 1 min.
Transmission physics (General)PROFIBUS-DP-compliant copper cable
Net weight (Ambient conditions)710 g
Switching rate (IO-Link inputs)1 per second, maximum (at nominal inductive load)
Number of ports (Digital inputs)4
Address area assignment (General)1 ... 126, adjustable
Degree of protection (Dimensions)IP65/IP67
Permissible cable length (Supply)< 20 m
Connection method (Digital inputs)M12 fast connection technology
Connection method (IO-Link inputs)M12 connector, X01 ... X04 have double occupancy
Mounting type (Ambient conditions)Wall mounting or DIN rail mounting; both with mounting plate.
Number of outputs (IO-Link inputs)max. 8
Output description (IO-Link inputs)IO-Link ports in digital output (DO) mode
Type of protection (IO-Link inputs)Overload protection
Nominal load, ohmic (IO-Link inputs)3.6 W (160 Ω, at nominal load)
Weight per Piece (excluding packing)710.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Housing material (Ambient conditions)Zinc die-cast
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Connection technology (Digital inputs)3-wire
Connection technology (IO-Link inputs)3-wire
Designation connection point (General)Copper cable
System-specific protocols (Interfaces)PROFIBUS protocols DP V1
Behavior with overload (IO-Link inputs)Shutdown with automatic restart
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (IO-Link inputs)24 V DC
Nominal voltage for I/O supply (Supply)24 V DC
Note on the connection method (General)B-coded
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Input name (Supply of the IO-Link ports)Digital inputs at pin 2 for type A ports
Nominal load, inductive (IO-Link inputs)3.6 VA (0.8 H, 160 Ω, at nominal load)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Input frequency (Supply of the IO-Link ports)0.5 kHz
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Utilization restriction (Key Commercial Data)1
Designation (System limits of the bus coupler)Actuators (UA)
Number of inputs (Supply of the IO-Link ports)max. 8 (EN 61131-2 type 1)
Connection method (Supply of the IO-Link ports)M12 connector, X01 ... X04 have double occupancy
Input filter time (Supply of the IO-Link ports)< 1000 µs
Nominal current for every IO-Link port (Supply)max. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables)
Type of protection (Supply of the IO-Link ports)Overload protection
Output current when switched off (IO-Link inputs)max. 300 µA
Output voltage when switched off (IO-Link inputs)max. 1 V
Supply voltage (System limits of the bus coupler)24 V DC
Maximum output current per device (IO-Link inputs)1.2 A
Total sensor current (Supply of the IO-Link ports)max. 1.6 A (from L+/L-)
Connection technology (Supply of the IO-Link ports)3-wire
Maximum output current per channel (IO-Link inputs)150 mA
Nominal input current (Supply of the IO-Link ports)typ. 3 mA
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Connection method (System limits of the bus coupler)M12 connector (T-coded)
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 %
Current consumption (System limits of the bus coupler)typ. 30 mA ±15 % (at 24 V DC)
Description of the input (Supply of the IO-Link ports)IO-Link ports in digital input (DI) mode
Number of positions (System limits of the bus coupler)4
Nominal input voltage UIN (Supply of the IO-Link ports)24 V DC
Sensor current per channel (Supply of the IO-Link ports)max. 200 mA (from L+/L-)
Nominal input current at UIN (Supply of the IO-Link ports)typ. 3 mA
Input voltage range "0" signal (Supply of the IO-Link ports)-0.3 V DC ... 5 V DC
Input voltage range "1" signal (Supply of the IO-Link ports)15 V DC ... 30 V DC
Nominal supply voltage range (System limits of the bus coupler)18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Limitation of the voltage induced on circuit interruption (IO-Link inputs)-15 V DC

Product Description

Axioline E-PROFIBUS device in metal housing with 8 IO-Link ports, 4 digital inputs, 24 V DC, M12 quick connect technology
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top