Key Specifications
:8 (With 1 channel assignment)
Depth:30 mm
Width:59.8 mm
Height:214 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
8 (With 1 channel assignment)
Depth30 mm
Width59.8 mm
Height214 mm
Cycle Time≥ 4 ms
Delay Timemax. 128 s (parameterizable)
Port ModelClass A
Min. Charge2.4 kΩ (10 mA at 24 V DC)
ObservationResistant to hazardous gas for operation (sulfur dioxide (SO)2), hydrogen sulfide (H2S))
applicationFunctional safety
Cable lengthmax. 200 m
ConstructionStand-Alone
DenominationIO-Link Port Power (L+)
Product TypeI/O Component
SpecificationV1.1.2
Operating Mode4-word process data service
Output currentmax. 2 A (per channel)
Output voltageUto- 1.4 V
Product FamilyAxioline E
Shell materialPlastic POCAN B4239 GF30 YE 1018
Supply voltage19.2 V DC ... 30.2 V DC (incl. all tolerances, incl. ripple)
Connection typeM12 plug-in connector (A-coded)
Fuse protectionmax. 8 A (slow)
Number of poles2
Number of ports1
Dimension Scheme
Protection IndexIP65/IP67 (according to DIN EN 60529:1989 + A1:1999 + A2:2013)
Inlet Filter Time1.5 ms
Number of Entries4 (With 2 channel assignment)
Number of outputs4 (with 2-channel assignment, +/- switching)
Current absorption67 mA (Without Sensors)
Denomination EntrySecure Digital Inputs
Kind of protectionIII (IEC 61140, EN 61140, VDE 0140-1)
Protection CircuitOverload protection, short-circuit protection of sensor power
Ticket DescriptionIEC 61131-2 Type 3
Transmission speed230.4 kBit/s (COM3)
Degree of pollution4
Denomination OutputSecure Digital Outputs
Number of manoeuvresmax. 1 Hz
Connection technology3 conductors
Position for mountingdiscretionary
Updating Process Data≥ 4 ms
Air Pressure (Service)70 kPa ... 108 kPa (up to 3000 m above NN)
Nominal Output Voltage24 V DC (Voltage Us)
Number of process data64 Bit (Input and Output Data)
Leak lines and air gapsaccording to IEC 60664-1
Permissible cable lengthmax. 50 m
Nominal Input Voltage UIN24 V DC
Nominal current per deviceapprox. 15 mA
Nominal input current to UINTyp. 3.7 mA (with 24 V DC)
Polarity reversal protectionYes
Ambient Temperature (Service)-25 °C ... 60°C (Mounting Position: Discretionary)
Input Voltage Range Signal "0"-30 V DC ... 5 V DC
Input Voltage Range Signal "1"11 V DC ... 30.2 V DC
Note about the connection typeaccording to IEC 61076-2-101, M12 connection technology
Note on Measurement IndicationsData incl. fixing tabs and plugs
Air Pressure (Storage/Transport)66 kPa ... 108 kPa (up to 3500 m above NN)
Nominal Peripheral Supply Voltage24 V DC (Made available via the IO-Link interface of the IO-Link master.)
Maximum Output Current Per Channel2 A
Output current in disconnected state2 mA (Leakage current in "Low" state)
Output voltage in disconnected state< 5 V (in Low state))
Ambient Temperature (Storage/Transport)-40 °C ... 85 °C
Permissible air humidity (storage/transport)75% (non-condensing)
Resistance to return voltage, against short impulsesNo

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top