Key Specifications
GTIN:4046356763509
Orderkey:2701496
(Supply):Short-circuit protection for the sensor supply
Catalog page:Page 195 (C-6-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356763509
Orderkey2701496
(Supply)Short-circuit protection for the sensor supply
Catalog pagePage 195 (C-6-2017)
Depth (Note)30.5 mm
Packing unit1 pc
Width (Note)60 mm
(Interfaces)DHCP
Height (Note)185 mm
(Digital inputs)Short-circuit protection
Country of originDE (Germany)
(Digital outputs)24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min.
Input name (Supply)Digital inputs at pin 2 for type A ports
Custom tariff number85176200
Designation (General)EtherNet/IP™
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)EtherNet/IP™
Input frequency (Supply)0.5 kHz
Drill hole spacing (Note)198.5 mm
No. of channels (General)2
Note on dimensions (Note)The height is 212 mm including fixing clips.
Number of inputs (Supply)max. 8 (EN 61131-2 type 1)
Connection method (Supply)M12 connector, X01 ... X04 have double occupancy
Dimensional drawing (Note)
Input filter time (Supply)< 1000 µs
Specification (Interfaces)CIP Edition 3.11EIP adaptation of CIP 1.12
Connection method (General)M12 fast connection technology
Equipment type (Interfaces)EtherNet/IP™ slave
Type of protection (Supply)Overload protection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Transmission speed (General)10/100 Mbps (with auto negotiation)
Number of positions (General)4
Signal delay (Digital inputs)max. 150 µs (when switched on)
Total sensor current (Supply)max. 1.6 A (from L+/L-)
Connection technology (Supply)3-wire
Nominal input current (Supply)typ. 3 mA
Test section (Digital outputs)24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
Net weight (Ambient conditions)552.8 g
Switching rate (Digital inputs)1 per second, maximum (at nominal inductive load)
Protocols supported (Interfaces)SNMP v1
Degree of protection (Dimensions)IP65/IP67
Description of the input (Supply)IO-Link ports in digital input (DI) mode
Connection method (Digital inputs)M12 connector, X01 ... X04 have double occupancy
Mounting type (Ambient conditions)Wall mounting
Nominal input voltage UIN (Supply)24 V DC
Number of outputs (Digital inputs)max. 8
Output description (Digital inputs)IO-Link ports in digital output (DO) mode
Sensor current per channel (Supply)max. 200 mA (from L+/L-)
Type of protection (Digital inputs)Overload protection
Nominal load, ohmic (Digital inputs)3.6 W (160 Ω, at nominal load)
Weight per Piece (excluding packing)552.800 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Housing material (Ambient conditions)Pocan®
Nominal input current at UIN (Supply)typ. 3 mA
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Connection technology (Digital inputs)3-wire
Designation connection point (General)Copper cable
System-specific protocols (Interfaces)EtherNet/IP™ protocols ACD
Behavior with overload (Digital inputs)Shutdown with automatic restart
Input voltage range "0" signal (Supply)-0.3 V DC ... 5 V DC
Input voltage range "1" signal (Supply)15 V DC ... 30 V DC
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (Digital inputs)24 V DC
Note on the connection method (General)D-coded
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, inductive (Digital inputs)3.6 VA (0.8 H, 160 Ω, at nominal load)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Utilization restriction (Key Commercial Data)1
Designation (System limits of the bus coupler)Actuators (UA)
Output current when switched off (Digital inputs)max. 300 µA
Output voltage when switched off (Digital inputs)max. 1 V
Supply voltage (System limits of the bus coupler)24 V DC
Maximum output current per device (Digital inputs)1.2 A
Maximum output current per channel (Digital inputs)150 mA
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Connection method (System limits of the bus coupler)M12 connector (T-coded)
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 %
Current consumption (System limits of the bus coupler)typ. 28 mA ±15 % (at 24 V DC)
Number of positions (System limits of the bus coupler)4
Nominal supply voltage range (System limits of the bus coupler)18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Limitation of the voltage induced on circuit interruption (Digital inputs)-15 V DC

Product Description

AxiolineE, EtherNet/IP™, M12 Quick Connect Technology, IO-Link Class A ports: 4, connection type: M12 Quick Connect Technology, connection technology: 3 conductors, IO-Link Class B ports: 4, connectio
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top