Service time: Monday to Friday 9:00-18:00
AXL E EIP IOL8 DI4 M12 6M - AXL E EIP IOL8 DI4 M12 6M 2701491 PHOENIX CONTACT Distributed I/O device
In Stock Hot Product

AXL E EIP IOL8 DI4 M12 6M

AXL E EIP IOL8 DI4 M12 6M 2701491 PHOENIX CONTACT Distributed I/O device

$0.00USD
3187 in stock
Key Specifications
GTIN:4046356762854
Note:Made to Order (non-returnable)
Orderkey:2701491
(Supply):Short-circuit protection for the sensor supply
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356762854
NoteMade to Order (non-returnable)
Orderkey2701491
(Supply)Short-circuit protection for the sensor supply
Catalog pagePage 195 (C-6-2017)
Depth (Note)38 mm
Packing unit1 pc
Width (Note)60 mm
(Interfaces)DHCP
Height (Note)185 mm
(Digital inputs)Short-circuit protection
Country of originDE (Germany)
(Digital outputs)24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min.
Input name (Supply)Digital inputs at pin 2 for type A ports
Custom tariff number85176200
Designation (General)EtherNet/IP™
(Electrical isolation)Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Designation (Interfaces)EtherNet/IP™
Input frequency (Supply)0.5 kHz
Drill hole spacing (Note)198.5 mm
No. of channels (General)2
Note on dimensions (Note)The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate).
Number of inputs (Supply)max. 8 (EN 61131-2 type 1)
Connection method (Supply)M12 connector, X01 ... X04 have double occupancy
Dimensional drawing (Note)
Input filter time (Supply)< 1000 µs
Specification (Interfaces)CIP Edition 3.11EIP adaptation of CIP 1.12
Connection method (General)M12 fast connection technology
Equipment type (Interfaces)EtherNet/IP™ slave
Type of protection (Supply)Overload protection
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Transmission speed (General)10/100 Mbps (with auto negotiation)
Number of positions (General)4
Signal delay (Digital inputs)max. 150 µs (when switched on)
Total sensor current (Supply)max. 1.6 A (from L+/L-)
Connection technology (Supply)3-wire
Nominal input current (Supply)typ. 3 mA
Test section (Digital outputs)24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min.
Net weight (Ambient conditions)721 g
Switching rate (Digital inputs)1 per second, maximum (at nominal inductive load)
Protocols supported (Interfaces)SNMP v1
Degree of protection (Dimensions)IP65/IP67
Description of the input (Supply)IO-Link ports in digital input (DI) mode
Connection method (Digital inputs)M12 connector, X01 ... X04 have double occupancy
Mounting type (Ambient conditions)Wall mounting or DIN rail mounting; both with mounting plate.
Nominal input voltage UIN (Supply)24 V DC
Number of outputs (Digital inputs)max. 8
Output description (Digital inputs)IO-Link ports in digital output (DO) mode
Sensor current per channel (Supply)max. 200 mA (from L+/L-)
Type of protection (Digital inputs)Overload protection
Nominal load, ohmic (Digital inputs)3.6 W (160 Ω, at nominal load)
Weight per Piece (excluding packing)721.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Housing material (Ambient conditions)Zinc die-cast
Nominal input current at UIN (Supply)typ. 3 mA
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Connection technology (Digital inputs)3-wire
Designation connection point (General)Copper cable
System-specific protocols (Interfaces)EtherNet/IP™ protocols ACD
Behavior with overload (Digital inputs)Shutdown with automatic restart
Input voltage range "0" signal (Supply)-0.3 V DC ... 5 V DC
Input voltage range "1" signal (Supply)15 V DC ... 30 V DC
Mechanical tests (Electrical isolation)Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Nominal output voltage (Digital inputs)24 V DC
Note on the connection method (General)D-coded
Protection class (Electrical isolation)III, IEC 61140, EN 61140, VDE 0140-1
Nominal load, inductive (Digital inputs)3.6 VA (0.8 H, 160 Ω, at nominal load)
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C
Air pressure (storage/transport) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 %
Utilization restriction (Key Commercial Data)1
Designation (System limits of the bus coupler)Actuators (UA)
Output current when switched off (Digital inputs)max. 300 µA
Output voltage when switched off (Digital inputs)max. 1 V
Supply voltage (System limits of the bus coupler)24 V DC
Maximum output current per device (Digital inputs)1.2 A
Maximum output current per channel (Digital inputs)150 mA
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 85 °C
Connection method (System limits of the bus coupler)M12 connector (T-coded)
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 %
Current consumption (System limits of the bus coupler)typ. 28 mA ±15 % (at 24 V DC)
Number of positions (System limits of the bus coupler)4
Nominal supply voltage range (System limits of the bus coupler)18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Limitation of the voltage induced on circuit interruption (Digital inputs)-15 V DC

Product Description

Axioline E, EtherNet/IP™, M12 quick connect technology, Digital inputs on pin 2 with type A ports: 4, 24 V DC, connection technology: 3 conductors, Metal housing, protection index: IP65/IP67
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top