AXC F 1050 - AXC F 1050 2404701 PHOENIX CONTACT Controller
In Stock Hot Product

AXC F 1050

AXC F 1050 2404701 PHOENIX CONTACT Controller

$0.00USD
4368 in stock
Key Specifications
GTIN:4055626426310
Note:Made to Order (non-returnable)
Orderkey:2404701
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626426310
NoteMade to Order (non-returnable)
Orderkey2404701
Packing unit1 pc
(Dimensions)-25 °C ... 55 °C up to 3000 m above mean sea level
Country of originDE (Germany)
(Data interfaces)min. 4 ms (1st device)
Shock (Dimensions)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Custom tariff number85371091
Shock (General data)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Weight (Power supply)225.6 g
Number (Fieldbus function)2
(IEC 61131 runtime system)max. 32768 Bit (per station)
Depth (Key Commercial Data)74 mm
Width (Key Commercial Data)45 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)125.9 mm
Power dissipation (PROFINET)max. 3 W
Immunity to EF (General data)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Interface (Fieldbus function)Ethernet
Mass storage (Control system)2 Mbyte
Processor (Mechanical design)Altera Nios II 1x 100 MHz
Update rate (Data interfaces)min. 32 ms (16 devices)
Immunity to ESD (General data)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Program memory (Control system)2 Mbyte
Realtime clock (Control system)Yes
Specification (Data interfaces)Version 2.3
Supply voltage range (PROFINET)19.2 V DC ... 30 V DC
Immunity to burst (General data)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to surge (General data)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Shock (operation) (General data)10g (Bump endurance test according to EN 60068-2-29)
Degree of protection (Dimensions)IP20
Device function (Data interfaces)PROFINET controller, PROFINET device
Engineering tool (Control system)PLCnext Engineer
Vibration (operation) (Dimensions)5g
Interference emission (General data)Noise emission test according to EN 61000-6-3 Radio noise emission EN 55032 Class B
Vibration (operation) (General data)5g
Weight per Piece (excluding packing)225.600 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Fieldbus function)RJ45 socket
Engineering tool (Ambient conditions)PLCnext Engineer
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Designation (IEC 61131 runtime system)
Transmission speed (Fieldbus function)10/100 Mbps
Configuration tool (Ambient conditions)Config+ Version 1.01 or later
Retentive mass storage (Control system)48 kByte (NVRAM)
Number of control tasks (Control system)8
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C up to 2000 m above mean sea level
Electromagnetic compatibility (General data)Conformance with EMC Directive 2014/30/EU
Vibration (storage/transport) (General data)5g
Air pressure (storage/transport) (Dimensions)58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Permissible humidity (operation) (Dimensions)10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Amount of process data (IEC 61131 runtime system)max. 4096 Bit (Axioline F local bus (input))
Immunity to conducted interference (General data)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Programming languages supported (Ambient conditions)Programming in acc. with IEC 61131-3
Permissible humidity (storage/transport) (Dimensions)10 % ... 95 % (according to DIN EN 61131-2, non-condensing, no ice formation)
Number of supported devices (IEC 61131 runtime system)max. 63 (per station)
Number of local bus devices that can be connected (IEC 61131 runtime system)max. 63 (observe current consumption)

Product Description

Axial control for the Axioline direct I/O control system. With 2 Ethernet interfaces and programmability in accordance with IEC 61131-3. Complete with connector and labeling surface.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide