| Parameter | Value |
|---|---|
| GTIN | 4055626231150 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2402985 |
| Catalog page | Page 7 (C-6-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Shock (Dimensions) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Custom tariff number | 85371098 |
| Weight (Control system) | 225.6 g |
| Number (Mechanical design) | 2 |
| Depth (Key Commercial Data) | 74 mm |
| Mass storage (General data) | 1 Mbyte |
| Width (Key Commercial Data) | 45 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 125.9 mm |
| Interface (Mechanical design) | Ethernet |
| Processor (Fieldbus function) | Altera Nios II 100 MHz |
| Program memory (General data) | 1 Mbyte |
| Realtime clock (General data) | Yes |
| Engineering tool (General data) | PC WORX |
| Safety function (Control system) | No |
| Shock (IEC 61131 runtime system) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Supply voltage (Data interfaces) | 24 V DC |
| Degree of protection (Dimensions) | IP20 |
| Residual ripple (Data interfaces) | ± 5 % |
| Vibration (operation) (Dimensions) | 5g |
| Power dissipation (Data interfaces) | max. 3 W |
| Diagnostics display (Control system) | No |
| Weight per Piece (excluding packing) | 246.300 g |
| Air pressure (operation) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Connection method (Mechanical design) | RJ45 socket |
| Engineering tool (Ambient conditions) | PC WORX |
| Retentive mass storage (General data) | 48 kByte (NVRAM) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Controller redundancy (Control system) | No |
| Number of control tasks (General data) | 8 |
| Supply voltage range (Data interfaces) | 19.2 V DC ... 30 V DC |
| Transmission speed (Mechanical design) | 10/100 Mbps |
| Noise emission (IEC 61131 runtime system) | EN 61000-6-4 |
| Noise immunity (IEC 61131 runtime system) | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 EN 61000-4-3 (radiated noise immunity) Criterion A, 10 V/m |
| Immunity to ESD (IEC 61131 runtime system) | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 EN 61000-4-2 (ESD) Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Max. current consumption (Data interfaces) | 160 mA |
| Number of supported devices (Power supply) | max. 63 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Immunity to burst (IEC 61131 runtime system) | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 EN 61000-4-4 (EFT burst) Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV |
| Immunity to surge (IEC 61131 runtime system) | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 EN 61000-4-5 (surge) Criterion B |
| Shock (operation) (IEC 61131 runtime system) | 10g (Bump endurance test according to DIN EN 60068-2-27) |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Typical current consumption (Data interfaces) | 125 mA |
| Interference emission (IEC 61131 runtime system) | Noise emission test as per EN 61000-6-4 EN 55011 (emitted interference) Class A |
| Vibration (operation) (IEC 61131 runtime system) | 5g |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Programming languages supported (Ambient conditions) | Programming in acc. with IEC 61131-3 |
| Permissible humidity (storage/transport) (Dimensions) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Electromagnetic compatibility (IEC 61131 runtime system) | Conformance with EMC Directive 2014/30/EU |
| Vibration (storage/transport) (IEC 61131 runtime system) | 5g |
| Immunity to conducted interference (IEC 61131 runtime system) | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 EN 61000-4-6 (line noise immunity) Criterion A; Test voltage 10 V |