Service time: Monday to Friday 9:00-18:00
AXC 3050 - AXC 3050 2700989 PHOENIX CONTACT Controller
In Stock Hot Product

AXC 3050

AXC 3050 2700989 PHOENIX CONTACT Controller

$0.00USD
4644 in stock
Key Specifications
GTIN:4046356731201
Orderkey:2700989
Catalog page:Page 77 (C-6-2017)
Depth (Note):74 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356731201
Orderkey2700989
Catalog pagePage 77 (C-6-2017)
Depth (Note)74 mm
Packing unit1 pc
Width (Note)100 mm
Height (Note)125.9 mm
Country of originDE (Germany)
Shock (Dimensions)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Custom tariff number85371091
Shock (General data)30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27
Input name (PROFINET)Counter input for 24 V signals
Weight (Power supply)444 g
Input frequency (PROFINET)max. 100 kHz (with AXL F DI16/1 HS 1H module)
Number (Fieldbus function)1
(IEC 61131 runtime system)max. 8192 Bit (internal Modbus /TCP client)
Number of inputs (PROFINET)max. 2 (via any digital inputs of the Axioline F modules)
(Standards and Regulations)No hazardous substances above threshold values
Supply voltage (Direct I/Os)24 V DC
Immunity to EF (General data)Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Interface (Fieldbus function)Service
Mass storage (Control system)8 Mbyte
Processor (Mechanical design)Intel®Atom™ E660 1x 1.3 GHz
Residual ripple (Direct I/Os)± 5 %
Update rate (Data interfaces)max. of 256 devices
Immunity to ESD (General data)Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Safety function (Power supply)No
Power dissipation (Direct I/Os)max. 9.8 W
Program memory (Control system)4 Mbyte
Realtime clock (Control system)Yes
Specification (Data interfaces)Version 2.3
Immunity to burst (General data)Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
Immunity to surge (General data)Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
Shock (operation) (General data)10g (Bump endurance test according to DIN EN 60068-2-27)
Degree of protection (Dimensions)IP20
Device function (Data interfaces)PROFINET controller, PROFINET device
Engineering tool (Control system)PC WORX
Diagnostics display (Power supply)No
Supply voltage range (Direct I/Os)19.2 V DC ... 30 V DC
Vibration (operation) (Dimensions)5g
Controller redundancy (Power supply)No
Interference emission (General data)Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class A
Vibration (operation) (General data)5g
Weight per Piece (excluding packing)444.000 g
Air pressure (operation) (Dimensions)70 kPa ... 106 kPa (up to 3000 m above sea level)
Connection method (Fieldbus function)USB type A, socket
Diagnostics tool (Ambient conditions)DIAG+
Engineering tool (Ambient conditions)PC WORX
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Max. current consumption (Direct I/Os)max. 976 mA (with 2 A at UBusfor the I/Os and UL= 24 V)
Transmission speed (Fieldbus function)max. 115.2 kbps
Configuration tool (Ambient conditions)Config+ Version 1.01 or later
Retentive mass storage (Control system)128 kByte
Number of control tasks (Control system)16
Typical current consumption (Direct I/Os)typ. 408 mA (without I/Os and UL= 24 V)
Ambient temperature (assembly) (Dimensions)-5 °C ... 60 °C
Ambient temperature (operation) (Dimensions)-25 °C ... 60 °C (up to 2000 m above sea level)
Electromagnetic compatibility (General data)Conformance with EMC Directive 2014/30/EU
Vibration (storage/transport) (General data)5g
Air pressure (storage/transport) (Dimensions)58 kPa ... 106 kPa (up to 4500 m above mean sea level)
Permissible humidity (operation) (Dimensions)5 % ... 95 % (according to DIN EN 61131-2)
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Amount of process data (IEC 61131 runtime system)max. 4096 Bit (Axioline F local bus (input))
Immunity to conducted interference (General data)Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Programming languages supported (Ambient conditions)Programming in acc. with IEC 61131-3
Permissible humidity (storage/transport) (Dimensions)5 % ... 95 % (according to DIN EN 61131-2)
Number of supported devices (IEC 61131 runtime system)max. 63 (per station)
Number of local bus devices that can be connected (IEC 61131 runtime system)max. 63 (observe current consumption)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top