| Parameter | Value |
|---|---|
| Customs Tariff Number: | 85364900 |
| Minimum Order Quantity: | 1 piece |
| RoHS Status: (Technical) | Following EU Directive 2011/65/EU |
| Operate Time: (Dimensions) | Between Coil Energization and NO Contact Closing 10 ... 25 msBetween Coil De-energization and NO Contact Opening 10 ... 18 msBetween Coil De-energization and NC Contact Closing 7 ... 15 msBetween Coil Energization and NC Contact Opening 7 ... 22 ms |
| Terminal Type: (Dimensions) | Cable Clamp |
| Dimension Diagram: (Ordering) | 53540923-1 |
| Replacement Product ID (NEW): | 1SBL407001R1311 |
| Coil Consumption: (Dimensions) | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 450 V·AHolding at Max. Rated Control Circuit Voltage 50 Hz 22 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 26 V·A |
| ETIM 4: (Container Information) | EC000066 - Magnet contactor, AC-switching |
| ETIM 5: (Container Information) | EC000066 - Magnet contactor, AC-switching |
| ETIM 6: (Container Information) | EC000066 - Power contactor, AC switching |
| ETIM 7: (Container Information) | EC000066 - Power contactor, AC switching |
| UNSPSC: (Container Information) | 39121529 |
| Rated Frequency (f): (Dimensions) | Main Circuit 50/60 Hz |
| BV Certificate: (Technical UL/CSA) | 07172/D0 BV |
| CB Certificate: (Technical UL/CSA) | SE-69430 |
| Degree of Protection: (Dimensions) | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| GL Certificate: (Technical UL/CSA) | GL_99358-97HH |
| LR Certificate: (Technical UL/CSA) | LR_12-70027-E1 |
| CCC Certificate: (Technical UL/CSA) | CQC_2002010304008904 |
| Coil Operating Limits: (Dimensions) | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C |
| DNV Certificate: (Technical UL/CSA) | DNV_E-12191 |
| Mechanical Durability: (Dimensions) | 10 million |
| Ambient Air Temperature: (Technical) | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °C |
| Instructions and Manuals: (Ordering) | 5309660-60 |
| RINA Certificate: (Technical UL/CSA) | ELE060313XG/001 |
| RMRS Certificate: (Technical UL/CSA) | RMRS_12-03683-315 |
| RoHS Information: (Technical UL/CSA) | 2CMT2016-006207 |
| LOVAG Certificate: (Technical UL/CSA) | SE-9645071-1 |
| Product Net Width: (Popular Downloads) | 102 mm |
| Maximum Breaking Capacity: (Dimensions) | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A |
| Product Net Height: (Popular Downloads) | 148 mm |
| Product Net Weight: (Popular Downloads) | 2.04 kg |
| Rated Operational Voltage: (Dimensions) | Main Circuit 1000 V |
| Number of Main Contacts NC: (Dimensions) | 0 |
| Number of Main Contacts NO: (Dimensions) | 3 |
| Horsepower Rating UL/CSA: (Environmental) | (208 V AC) Three Phase 30 Hp(440 ... 480 V AC) Three Phase 60 Hp(550 ... 600 V AC) Three Phase 75 Hp(220 ... 240 V AC) Three Phase 30 Hp(200 V AC) Three Phase 30 Hp |
| E-Number (Norway): (Container Information) | 3229999 |
| E-Number (Sweden): (Container Information) | 3229999 |
| General Use Rating UL/CSA: (Environmental) | (600 V AC) 125 A |
| Rated Insulation Voltage (Ui): (Dimensions) | acc. to UL/CSA 600 Vacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Instructions and Manuals: (Technical UL/CSA) | 5309660-60 |
| Data Sheet, Technical Information: (Ordering) | 1SBC100192C0206 |
| Environmental Information: (Technical UL/CSA) | 1SFC101001D0201 |
| Number of Auxiliary Contacts NC: (Dimensions) | 1 |
| Number of Auxiliary Contacts NO: (Dimensions) | 1 |
| Connecting Capacity Main Circuit: (Dimensions) | Flexible with Cable End 2 x 6 ... 35 mm²Bar 30 mm²Rigid 1 x 10 ... 95 mm² |
| Short-Circuit Protective Devices: (Dimensions) | gG Type Fuses 160 A |
| Product Net Depth / Length: (Popular Downloads) | 123.5 mm |
| Rated Operational Power AC-3 (Pe): (Dimensions) | (500 V) 55 kW(1000 V) 40 kW(690 V) 55 kW(220 / 230 / 240 V) 25 kW(380 / 400 V) 45 kW(440 V) 55 kW(415 V) 55 kW |
| Rated Control Circuit Voltage (Uc): (Dimensions) | 60 Hz 230 ... 240 V50 Hz 220 ... 230 V |
| Maximum Operating Voltage UL/CSA: (Environmental) | Main Circuit 600 V |
| Rated Operational Current AC-1 (Ie): (Dimensions) | (690 V) 55 °C 135 A(690 V) 40 °C 145 A(690 V) 70 °C 115 A |
| Rated Operational Current AC-3 (Ie): (Dimensions) | (1000 V) 55 °C 30 A(415 V) 55 °C 96 A(690 V) 55 °C 65 A(220 / 230 / 240 V) 55 °C 96 A(440 V) 55 °C 93 A(380 / 400 V) 55 °C 96 A(500 V) 55 °C 80 A |
| Rated Operational Current DC-1 (Ie): (Dimensions) | (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-3 (Ie): (Dimensions) | (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-5 (Ie): (Dimensions) | (110 V) 2 Poles in Series, 40 °C 145 A(220 V) 3 Poles in Series, 40 °C 145 A |
| Declaration of Conformity - CE: (Technical UL/CSA) | 2CMT2015-005436 |
| Connecting Capacity Auxiliary Circuit: (Dimensions) | Solid 2 x 1 ... 4 mm²Flexible with Insulated Ferrule 2 x 0.75 ... 2.5 mm²Stranded 2 x 1 .... 4 mm²Flexible 2x0.75 ... 2.5 mm²Flexible with Ferrule 2 x 0.75 ... 2.5 mm² |
| Maximum Operating Altitude Permissible: (Technical) | 3000 m |
| Object Classification Code: (Container Information) | Q |
| Maximum Electrical Switching Frequency: (Dimensions) | AC-3 300 cycles per hourAC-1 300 cycles per hourAC-2 / AC-4 150 cycles per hour |
| Maximum Mechanical Switching Frequency: (Dimensions) | 3600 cycles per hour |
| Rated Impulse Withstand Voltage (Uimp): (Dimensions) | Main Circuit 8 kV |
| Rated Short-time Withstand Current (Icw): (Dimensions) | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A |
| Resistance to Shock acc. to IEC 60068-2-27: (Technical) | Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 gHalf-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g |
| Conventional Free-air Thermal Current (Ith): (Dimensions) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 145 A |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1: (Dimensions) | 10 x Ie AC-3 |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: (Dimensions) | 8 x Ie AC-3 |
| Package Level 1 EAN: (Certificates and Declarations (Document Number)) | 7320500142776 |
| Package Level 1 Units: (Certificates and Declarations (Document Number)) | box 1 piece |
| Package Level 1 Width: (Certificates and Declarations (Document Number)) | 140 mm |
| Package Level 1 Height: (Certificates and Declarations (Document Number)) | 170 mm |
| Connecting terminals (delivered in open position) Main poles: (Dimensions) | M8 hexagon socket screw with single connector |
| Package Level 1 Gross Weight: (Certificates and Declarations (Document Number)) | 2 kg |
| Package Level 1 Depth / Length: (Certificates and Declarations (Document Number)) | 140 mm |
Technical specifications and performance data