| Parameter | Value |
|---|---|
| Item (Slim-size safety unit) | G9SB-200_-_ |
| 2 channels (Slim-size safety unit) | Manual-reset |
| Durability (Slim-size safety unit) | Mechanical |
| Electrical (Slim-size safety unit) | 100,000 operations min. (at approx. 1,800 operations/hr) |
| Rated load (Slim-size safety unit) | 250 VAC, 5 A |
| Input current (Slim-size safety unit) | 25 mA max. |
| Main contacts (Slim-size safety unit) | Auxiliary contact |
| Response time (Slim-size safety unit) | 10 ms max. |
| Power consumption (Slim-size safety unit) | 1.4 VA/1.4 W max. |
| Rated carry current (Slim-size safety unit) | 5 A |
| Power supply voltage (Slim-size safety unit) | 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24VDC24 VDC: 24 VDC |
| 1 channel or2 channels (Slim-size safety unit) | + common |
| 3PST-NO3 safetycontacts (Slim-size safety unit) | SPST-NC |
| DPST-NO2 safetycontacts (Slim-size safety unit) | None |
| Operating voltage range (Slim-size safety unit) | 85 to 110% of rated power supply voltage |
| Ambient operating temperature (Slim-size safety unit) | -25°C +55°C (with no icing or condensation) |
| Minimum permissable load (reference value) (Slim-size safety unit) | 5 VDC, 1 mA |
Technical specifications and performance data