| Parameter | Value |
|---|---|
| EAN | 4001869563695 |
| UPC | Not available |
| ETIM | 5 |
| depth | 63 mm |
| width | 71.6 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 90 mm |
| Group Code | P360 |
| net weight | 280 g |
| ● maximum | 415 V |
| ● minimum | 50 V |
| Confirmation | |
| Date5/6/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| Product Group | 5765 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| voltage curve | Sinusoidal or distorted |
| Commodity Code | 90303370 |
| Product family | 7KT PAC1600 Measuring Devices |
| number of keys | 4 |
| Net Weight (kg) | 0,284 Kg |
| product function | |
| ● set at 50 Hz | No |
| ● set to 60 Hz | No |
| Country of origin | Italy |
| mounting position | any |
| ● initial value | 45 Hz |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| measurable current | |
| product brand name | SENTRON |
| Packaging Dimension | 123,00 x 136,00 x 108,00 |
| Product Description | SENTRON, measuring device, 7KT PAC1600, LCD, L-L: 400 V, L-N: 230 V, 5 A, strd rail instr., 3-phase, Modbus RTU/ASCII, power monitoring incl. THD, AC/DC, screw terminals |
| degree of pollution | 2 |
| measuring procedure | |
| product designation | 7KM PAC1600 |
| Voltmeter (EF006560) | true |
| ● full-scale value | 66 Hz |
| design of the display | LCD |
| design of the product | basic |
| Ampere meter (EF006555) | true |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● 1 at AC rated value | 5 A |
| ● 2 at AC rated value | 5 A |
| ● current measurement | Yes |
| ● voltage measurement | Yes |
| General Product Approval | Declaration of Conformity |
| Pulse counter (EF006559) | false |
| number of digital inputs | 0 |
| product type designation | Measuring instrument |
| type of switching output | solid state |
| measurable line frequency | |
| number of digital outputs | 0 |
| suitability for operation | Standard mounting rail device |
| ● frequency measurement | Yes |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Frequency meter (EF006558) | true |
| design of the power supply | Wide-range power supply |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| ● for current measurement | TRMS |
| ● for voltage measurement | TRMS |
| Blind power meter (EF006556) | true |
| Package size unit of measure | MM |
| ● active power measurement | Yes |
| type of electrical connection | |
| ● reactive power measurement | Yes |
| size of Power Monitoring Device | 4MW |
| protection class IP on the front | IP40 |
| type of measured value detection | complete |
| relative measurable current at AC | |
| ambient temperature during storage | |
| ambient temperature during operation | |
| Article Number (Market Facing Number) | 7KT1682 |
| type of voltage of the supply voltage | AC/DC |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With rotational speed meter (EF006557) | false |
| fastening method standard rail mounting | Yes |
| reference condition for metering accuracy | Acc. to IEC62053-21 and IEC62053-23 |
| ● at the measurement inputs for current | screw-type terminals |
| ● at the measurement inputs for voltage | screw-type terminals |
| measuring category for current measurement | CATIII |
| measuring category for voltage measurement | CATIII |
| operating mode for measured value detection | |
| Effective power measurement device (EF006561) | true |
| zero point suppression for current measurement | 25 mA |
| measurable supply voltage between (PE)N and L at AC | |
| Region Specific PriceGroup / Headquarter Price Group | 15C / 1DD |
| type of electrical connection at the digital outputs | screw-type terminals |
| installation altitude at height above sea level maximum | 2 000 m |
| operating conditions for digital inputs external voltage supply | No |
| current measuring range extension with external current transformers | yes |
| voltage measuring range extension with external voltage transformers | yes |
| Compliance with the substance restrictions according to RoHS directive | Since: 06.11.2017 |
| measurable supply voltage between (PE)N and L at AC maximum rated value | 230 V |
| REACH Art. 33 Duty to inform according to the current list of candidates | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
| relative humidity at 25 °C without condensation during operation maximum | 80 % |
| operating mode for measured value detection automatic line frequency detection | Yes |
| measurable supply voltage between the line conductors at AC maximum rated value | 400 V |
| General Product ApprovalDeclaration of ConformityotherConfirmationUK Declaration of ConformityMiscellaneous | General Product Approval |
Technical specifications and performance data
Installation and operation guide