| Parameter | Value |
|---|---|
| EAN | 4001869538631 |
| UPC | Not available |
| ETIM | 5 |
| depth | 64 mm |
| width | 108 mm |
| UNSPSC | 15 |
| eClass | 6 |
| height | 90 mm |
| Group Code | P360 |
| ● maximum | 276 V |
| ● minimum | 46 V |
| Confirmation | |
| Date5/5/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| Product Group | 5308 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| voltage curve | Sinusoidal or distorted |
| Commodity Code | 90303370 |
| Product family | SENTRON 7KM PAC Measuring Devices |
| number of keys | 4 |
| Net Weight (kg) | 0,389 Kg |
| product function | |
| ● set at 50 Hz | No |
| ● set to 60 Hz | No |
| Country of origin | Hungary |
| mounting position | any |
| ● initial value | 45 Hz |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| installation depth | 70.8 mm |
| measurable current | |
| product brand name | SENTRON |
| Packaging Dimension | 123,00 x 136,00 x 108,00 |
| Product Description | SENTRON, measuring device, 7KM PAC3200T, strd mnt. rail encl. w/o display, L-L: 400 V, L-N: 230 V, 5 A, strd rail instr., 3-phase, MODBUS TCP, apparent /active/reactive energy, wide-range pwr sup. unit AC/DC, screw terminals |
| measuring procedure | |
| product designation | 7KM PAC3200T |
| Voltmeter (EF006560) | false |
| ● full-scale value | 65 Hz |
| design of the display | Standard mounting rail enclosure without display |
| design of the product | basic |
| Ampere meter (EF006555) | false |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● 1 at AC rated value | 1 A |
| ● 2 at AC rated value | 5 A |
| ● current measurement | Yes |
| ● voltage measurement | Yes |
| General Product Approval | EMC |
| Pulse counter (EF006559) | false |
| number of digital inputs | 1 |
| product type designation | Measuring instrument |
| type of switching output | solid state |
| measurable line frequency | |
| number of digital outputs | 1 |
| suitability for operation | Standard mounting rail device |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Frequency meter (EF006558) | false |
| design of the power supply | Wide-range power supply |
| Standard lead time ex-works | 120 Day/Days |
| Surcharge for Raw Materials | None |
| ● for current measurement | TRMS |
| ● for voltage measurement | TRMS |
| Blind power meter (EF006556) | false |
| Package size unit of measure | MM |
| transfer rate 1 for Ethernet | 10 Mbit/s |
| transfer rate 2 for Ethernet | 100 Mbit/s |
| ● active power measurement | Yes |
| type of electrical connection | |
| ● reactive power measurement | Yes |
| size of Power Monitoring Device | 6MW |
| type of measured value detection | complete |
| relative measurable current at AC | |
| ● for neutral conductor current | 45 mA |
| Article Number (Market Facing Number) | 7KM3200-0CA01-1AA0 |
| type of voltage of the supply voltage | AC/DC |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With rotational speed meter (EF006557) | false |
| fastening method standard rail mounting | Yes |
| reference condition for metering accuracy | In accordance with IEC61557-12, IEC62053-22 and IEC62053-23 |
| ● at the measurement inputs for current | screw-type terminals |
| ● at the measurement inputs for voltage | screw-type terminals |
| measuring category for current measurement | CATIII |
| measuring category for voltage measurement | CATIII |
| operating mode for measured value detection | |
| Effective power measurement device (EF006561) | false |
| zero point suppression for current measurement | 10 mA |
| protocol at the Ethernet interface is supported | MODBUS TCP |
| measurable supply voltage between (PE)N and L at AC | |
| Region Specific PriceGroup / Headquarter Price Group | 15N / 1DD |
| type of electrical connection at the digital outputs | screw-type terminals |
| operating conditions for digital inputs external voltage supply | Yes |
| current measuring range extension with external current transformers | yes |
| voltage measuring range extension with external voltage transformers | yes |
| Compliance with the substance restrictions according to RoHS directive | Since: 30.01.2017 |
| measurable supply voltage between (PE)N and L at AC maximum rated value | 230 V |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| operating mode for measured value detection automatic line frequency detection | Yes |
| measurable supply voltage between the line conductors at AC maximum rated value | 400 V |
| line conductors and neutral conductors internal resistance for voltage measurement | 1 MΩ |
| General Product ApprovalEMCDeclaration of ConformityotherConfirmationUK Declaration of ConformityMiscellaneous | General Product Approval |
Technical specifications and performance data