| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209835238 |
| UPC | 040892190830 |
| ETIM | 4 |
| Depth | 56 mm |
| Width | 96 mm |
| Height | 96 mm |
| UNSPSC | 14 |
| eClass | 6 |
| Protocol | |
| Standard | |
| ● solid | 1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²) |
| Group Code | P360 |
| net weight | 469 g |
| Price Group | 15N |
| ● maximum | 65 Hz |
| ● minimum | 45 Hz |
| Cutout width | 92 mm |
| Metal Factor | None |
| Cutout height | 92 mm |
| Product Group | 5310 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Transfer rate | |
| Voltage curve | Sinusoidal or distorted |
| Commodity Code | 90303100 |
| Output current | |
| Product family | 7KM PAC Measuring Devices |
| Pulse duration | |
| number of keys | 4 |
| Net Weight (kg) | 0,428 Kg |
| ● is supported | Modbus RTU |
| ● set at 50 Hz | No |
| ● set to 60 Hz | No |
| Country of origin | Hungary |
| mounting position | vertical |
| ● initial value | 30 ms |
| LKZ_FDB/ CatalogID | LV10.1 |
| Measurable current | |
| Packaging Quantity | 1 |
| installation depth | 51 mm |
| product brand name | SENTRON |
| Packaging Dimension | 115,00 x 135,00 x 85,00 |
| Product Description | SENTRON, measuring device, 7KM PAC3100, LCD, L-L: 480 V, L-N: 277 V, 3-phase, Modbus RTU, active/reactive energy, class 1 acc. to IEC 61557-12 & 62053- 21, wide-range power sup. unit AC/DC, screw terminals |
| Product designation | 7KM PAC3100 |
| ● at DC / maximum | 30 V |
| Voltmeter (EF006560) | false |
| ● Full-scale value | 500 ms |
| Design of the product | basic |
| design of the display | LCD |
| ● for pulse emitter | according to IEC62053-31 |
| Digital output version | switching or pulse output function |
| Ampere meter (EF006555) | false |
| Height / of the display | 54 mm |
| Product Lifecycle (PLM) | PM300:Active Product |
| General Product Approval | Declaration of Conformity |
| Product type designation | Measuring instrument |
| Pulse counter (EF006559) | false |
| Type of switching output | bidirectional |
| number of digital inputs | 2 |
| Measurable supply voltage | |
| Refresh time / on display | |
| Suitability for operation | Installation in stationary control panels in closed rooms |
| number of digital outputs | 2 |
| ● at the digital inputs | screw-type terminals |
| Apparent power consumption | |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Frequency meter (EF006558) | false |
| Vertical screen resolution | 96 |
| design of the power supply | Wide-range power supply |
| ● Width / of the display | 72 mm |
| ● at the digital outputs | screw-type terminals |
| Horizontal image resolution | 128 |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| ● 1 / at AC / Rated value | 5 A |
| Blind power meter (EF006556) | false |
| Package size unit of measure | MM |
| ● for signal <1> / minimum | 2.5 mA |
| Design of the switching input | Self-supplied |
| Type of electrical connection | |
| ● at AWG conductors / solid | 1x 24 ... 12 |
| ● for EMC against unloading | IEC 61000-4-2 |
| Mounting type / panel mounting | Yes |
| Product Dimensions (W x L x H) | Not available |
| Input current / at digital input | |
| Input voltage / at digital input | |
| Output delay / at digital output | |
| Type of measured value detection | complete |
| adjustable time period / minimum | 10 ms |
| ● for EMC for industrial sector | IEC 61000-6-2 respectively IEC 61326-1:2005, table 2 |
| ● for neutral conductor current | 45 mA |
| Load resistance / at digital input | |
| ● for EMC against surge voltages | IEC 61000-4-5 |
| Input delay time / at digital input | |
| Relative measurable current / at AC | |
| ● Protection class IP / Rear side | IP20 |
| ● for signal <0> to <1> / maximum | 5 ms |
| ● for signal <1> to <0> / maximum | 5 ms |
| Ambient temperature / during storage | |
| ● at the inputs for supply voltage | screw-type terminals |
| ● for environmental coldness check | IEC 60068-2-1 |
| ● for environmental dry heat check | IEC 60068-2-2 |
| Article Number (Market Facing Number) | 7KM3133-0BA00-3AA0 |
| Ambient temperature / during operation | |
| Supply voltage frequency / rated value | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With rotational speed meter (EF006557) | false |
| ● automatic line frequency detection | Yes |
| ● protection class IP / on the front | IP65 |
| ● without expansion module / typical | 10 V·A |
| Measuring category / for supply voltage | CATIII |
| Type of voltage / of the supply voltage | AC/DC |
| Color / of the background of the display | white |
| Measuring category / for digital signals | CATI |
| ● product function / pulse measurement | No |
| Material thickness / of the control panel | |
| Measurable line frequency / initial value | 45 Hz |
| ● at the measurement inputs for current | screw-type terminals |
| ● at the measurement inputs for voltage | screw-type terminals |
| ● between (PE)N and L / at AC / maximum | 277 V |
| ● between (PE)N and L / at AC / minimum | 11.5 V |
| ● for EMC against high frequency fields | IEC 61000-4-3 |
| ● product function / current measurement | Yes |
| ● product function / voltage measurement | Yes |
| Operating mode for measured value detection | |
| Reference condition / for metering accuracy | according to IEC61557-12 (K55) |
| ● initial value for signal<0>-recognition | 100 000 Ω |
| ● initial value for signal<1>-recognition | 2.5 mA |
| ● reference code / acc. to DIN EN 61346-2 | P |
| Internal resistance / at the digital outputs | 55 Ω |
| Measurable line frequency / Full-scale value | 65 Hz |
| Measuring category / for current measurement | CATIII |
| Measuring category / for voltage measurement | CATIII |
| Type of connectable conductor cross-sections | |
| property of the output / short-circuit proof | Yes |
| ● at the digital outputs / at DC / maximum | 30 mA |
| ● product function / frequency measurement | Yes |
| Effective power measurement device (EF006561) | false |
| Measuring procedure / for current measurement | TRMS |
| Measuring procedure / for voltage measurement | TRMS |
| ● for cyclic, environmental damp heat check | IEC 60068-2-30 |
| ● Full-scale value for signal<0> recognition | 0.5 mA |
| ● Full-scale value for signal<1> recognition | 1 000 Ω |
| ● finely stranded / with core end processing | 1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²) |
| ● product function / active power measurement | Yes |
| Continuous current / at AC / maximum permissible | 10 A |
| Zero-point suppression / for current measurement | 10 mA |
| ● at digital output / for signal <1> / maximum | 27 mA |
| ● at digital output / for signal <1> / minimum | 10 mA |
| Switching frequency / at digital output / maximum | 17 Hz |
| ● at digital output / with signal <0> / maximum | 0.2 mA |
| ● at the measurement inputs for current / solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| ● at the measurement inputs for voltage / solid | 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) |
| ● product function / reactive power measurement | Yes |
| Size of Power Monitoring Device / company-specific | size 96 |
| ● Product function / display contrast adjustable | Yes |
| ● between the outer conductors / at AC / maximum | 480 V |
| ● between the outer conductors / at AC / minimum | 20 V |
| ● Certificate of suitability / Approval Australia | Yes |
| ● for EMC against voltage drops and interruptions | IEC 61000-4-11 |
| Operating resource protection class / when installed | II |
| ● Certificate of suitability / as approval for USA | UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 |
| ● between (PE)N and L / at AC / maximum rated value | 277 V |
| Relative symmetrical tolerance / of the supply voltage | 10 % |
| ● Certificate of suitability / as approval for Canada | UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 |
| National language / on the display screen / is supported | ger, en, fr, spa, ita, por, tur, chi |
| Consumed active power / for current measurement / per phase | 500 mW |
| Installation altitude / at height above sea level / maximum | 2 000 m |
| ● for EMC against quick, transient electrical disturbances | IEC 61000-4-4 |
| ● between the outer conductors / at AC / maximum rated value | 480 V |
| ● Certificate of suitability / as EC declaration of conformity | IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1" |
| ● at the digital outputs / at DC / limited to 100 ms / maximum | 130 mA |
| Operating conditions for digital inputs / external voltage supply | No |
| ● for EMC against conducted disturbance variables via HF fields | IEC 61000-4-6 |
| Operating voltage / as output voltage / at DC / maximum permissible | 30 V |
| Type of connectable conductor cross-sections / at the digital inputs | |
| Type of connectable conductor cross-sections / at the digital outputs | |
| ● Product function / illuminance of display backlighting adjustable | No |
| ● at the measurement inputs for current / at AWG conductors / solid | 2x 20 to 14 |
| ● at the measurement inputs for voltage / at AWG conductors / solid | 2x 20 to 14 |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.07.2006 |
| Current measuring range extension / with external current transformers | Yes |
| Voltage measuring range extension / with external voltage transformers | Yes |
| ● for EMC against magnetic fields with power engineering frequencies | IEC 61000-4-8 |
| Product function / Display can be inverted (positive <=> negative mode) | Yes |
| Relative humidity / at 25 °C / without condensation / during operation | |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Supply voltage / between the outer conductors / at AC / maximum permissible | 576 V |
| Type of connectable conductor cross-sections / at the inputs for supply voltage | |
| Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 | P |
| ● Formula for relative total measurement inaccuracy / for measured variable output | +/- 1.0 % |
| Outer conductors and neutral conductors internal resistance / for voltage measurement | 0.84 MΩ |
| ● Formula for relative total measurement inaccuracy / for measured variable current | +/- 1.0 % |
| ● Formula for relative total measurement inaccuracy / for measured variable voltage | +/- 1.0 % |
| ● at the measurement inputs for current / finely stranded / with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| ● at the measurement inputs for voltage / finely stranded / with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
| General Product ApprovalDeclaration of ConformityotherConfirmationManufacturer Declaration | General Product Approval |
| ● formula for relative total measurement inaccuracy / for measured variable active power | +/- 1 % |
| ● Formula for relative total measurement inaccuracy / for measured variable active energy | Class 1 according to IEC 61557-12 and IEC62053-21 |
| ● Formula for relative total measurement inaccuracy / for measured variable output factor | +/- 1 % |
| ● formula for relative total measurement inaccuracy / for measured variable reactive power | +/- 3 % |
| ● Formula for relative total measurement inaccuracy / for measured variable reactive energy | Class 3 according to IEC61557-12 and IEC62053-23 |
| ● apparent power consumption / for current measurement / with measuring range 5 A / per phase | 0.5 V·A |
| ● Product function / Time-controlled reduction of the illuminance of display backlighting possible | Yes |
Technical specifications and performance data
Installation and operation guide