| Parameter | Value |
|---|---|
| Miscellaneous | |
| EAN | 4001869569994 |
| UPC | Not available |
| ETIM | 5 |
| depth | 56 mm |
| width | 96 mm |
| eClass | 6 |
| height | 96 mm |
| Group Code | P360 |
| net weight | 325 g |
| ● maximum | 480 V |
| ● minimum | 11.5 V |
| Confirmation | |
| Date5/4/2022 | Subject to change without notice© Copyright Siemens 2022 |
| Metal Factor | None |
| Product Group | 5310 |
| Product class | B: return restricted, please contact your Siemens partner/contact |
| Quantity Unit | 1 Piece |
| voltage curve | Sinusoidal or distorted |
| Commodity Code | 90303370 |
| Product family | SENTRON 7KM PAC Measuring Devices |
| number of keys | 4 |
| output current | |
| pulse duration | |
| Net Weight (kg) | 0,437 Kg |
| product function | |
| ● set at 50 Hz | No |
| ● set to 60 Hz | No |
| Country of origin | Hungary |
| mounting position | vertical |
| ● initial value | 45 Hz |
| LKZ_FDB/ CatalogID | LV10 |
| Packaging Quantity | 1 |
| installation depth | 51 mm |
| measurable current | |
| product brand name | SENTRON |
| Packaging Dimension | 96,00 x 58,00 x 96,00 |
| Product Description | SENTRON PAC3120 LCD 96X96 mm Power Monitoring Device Controll panel instrument for electrical values protocol: Modbus RTU with graphics display U rated input: 690/400V 45-65Hz IE rated input: X/1A oder X/5A AC Power supply: 100 ... 250 V +-10 % AC/DC screw connections |
| degree of pollution | 2 |
| measuring procedure | |
| product designation | 7KM PAC3120 |
| width of the display | 72 mm |
| ● full-scale value | 65 Hz |
| design of the display | LCD |
| design of the product | basic |
| height of the display | 54 mm |
| digital output version | switching or pulse output function |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● 1 at AC rated value | 1 A |
| ● 2 at AC rated value | 5 A |
| ● current measurement | Yes |
| ● voltage measurement | Yes |
| General Product Approval | EMC |
| number of digital inputs | 2 |
| product type designation | Measuring instrument |
| type of switching output | bidirectional |
| Declaration of Conformity | other |
| measurable line frequency | |
| number of digital outputs | 2 |
| suitability for operation | Installation in stationary control panels in closed rooms |
| ● frequency measurement | Yes |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| design of the power supply | Wide-range power supply |
| standard for pulse emitter | according to IEC62053-31 |
| Standard lead time ex-works | 180 Day/Days |
| Surcharge for Raw Materials | None |
| display contrast adjustable | Yes |
| ● for current measurement | TRMS |
| ● for voltage measurement | TRMS |
| Package size unit of measure | MM |
| ● active power measurement | Yes |
| type of electrical connection | |
| adjustable time period minimum | 10 ms |
| input current at digital input | |
| ● reactive power measurement | Yes |
| size of Power Monitoring Device | size 96 |
| protection class IP on the front | IP65 |
| type of measured value detection | complete |
| relative measurable current at AC | |
| ● for measured variable current | +/- 0,2 % |
| ● for measured variable voltage | +/- 0,2 % |
| ambient temperature during storage | |
| ambient temperature during operation | |
| Article Number (Market Facing Number) | 7KM3120-0BA01-1DA0 |
| type of voltage of the supply voltage | AC/DC |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| color of the background of the display | white |
| ● for measured variable active power | +/- 0.5 % |
| fastening method standard rail mounting | No |
| ● for measured variable active energy | Cl. 0.5 acc. to... IEC62053-22 |
| ● for measured variable output factor | +/- 0,5 % |
| ● for measured variable reactive power | +/- 1 % |
| reference condition for metering accuracy | In accordance with IEC61557-12, IEC62053-22 and IEC62053-23 |
| ● at the measurement inputs for current | screw-type terminals |
| ● at the measurement inputs for voltage | screw-type terminals |
| ● for measured variable reactive energy | Class 2 according to IEC61557-12 and/or IEC62053-23 |
| internal resistance at the digital outputs | 55 Ω |
| measuring category for current measurement | CATIII |
| measuring category for voltage measurement | CATIII |
| property of the output short-circuit proof | Yes |
| illuminance of display backlight adjustable | No |
| operating mode for measured value detection | |
| ● initial value for signal<1>-recognition | 7 mA |
| input voltage at digital input at DC maximum | 30 V |
| switching frequency at digital output maximum | 17 Hz |
| zero point suppression for current measurement | 0 ... 10 % |
| formula for relative total measurement inaccuracy | |
| measurable supply voltage between (PE)N and L at AC | |
| type of electrical connection at the digital inputs | screw-type terminals |
| Region Specific PriceGroup / Headquarter Price Group | 15N / 1DD |
| national language on the display screen is supported | de, en, fr, spa, ita, por, tur, chi, pol |
| type of electrical connection at the digital outputs | screw-type terminals |
| installation altitude at height above sea level maximum | 2 000 m |
| certificate of suitability as EC Declaration of Conformity | yes |
| ● at the digital outputs at DC limited to 100 ms maximum | 130 mA |
| operating voltage as output voltage at DC maximum permissible | 30 V |
| operating conditions for digital inputs external voltage supply | Yes |
| current measuring range extension with external current transformers | yes |
| voltage measuring range extension with external voltage transformers | yes |
| Compliance with the substance restrictions according to RoHS directive | Since: 30.08.2019 |
| measurable supply voltage between (PE)N and L at AC maximum rated value | 400 V |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| relative humidity at 25 °C without condensation during operation maximum | 75 % |
| time-controlled reduction of the illuminance of display backlight possible | Yes |
| operating mode for measured value detection automatic line frequency detection | Yes |
| measurable supply voltage between the line conductors at AC maximum rated value | 690 V |
| line conductors and neutral conductors internal resistance for voltage measurement | 1.5 MΩ |
| General Product ApprovalEMCDeclaration of ConformityConfirmationKCUK Declaration of ConformityDeclaration of ConformityotherMiscellaneous | General Product Approval |
Technical specifications and performance data
Installation and operation guide