Service time: Monday to Friday 9:00-18:00
7KM2112-0BA00-3AA0 - 7KM2112-0BA00-3AA0 SIEMENS SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase..
In Stock Hot Product

7KM2112-0BA00-3AA0

7KM2112-0BA00-3AA0 SIEMENS SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase..

$0.00USD
3494 in stock
Key Specifications
:Value
EAN:4011209725270
UPC:783643371835
ETIM:4
Supplier Information
SIEMENS
SIEMENS
Products: 367174
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Value
EAN4011209725270
UPC783643371835
ETIM4
MTBF185.8 y
Depth56 mm
Width96 mm
Height96 mm
UNSPSC14
eClass6
Protocol
Standard
● solid1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²)
Group CodeP360
net weight451 g
Price Group15N
● maximum45 Hz
● minimum65 Hz
Cutout width92 mm
Metal FactorNone
Cutout height92 mm
Product Group5308
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
Quantity Unit1 Piece
Transfer rate
Voltage curveSinusoidal or distorted
Commodity Code90303100
Output current
Product family7KM PAC Measuring Devices
Pulse duration
number of keys4
Net Weight (kg)0,427 Kg
● is supportedModbus TCP
● set at 50 HzNo
● set to 60 HzNo
Country of originHungary
mounting positionvertical
● for free fallIEC 60068-2-32: 1975
● initial value30 ms
LKZ_FDB/ CatalogIDLV10.1
Measurable current
Packaging Quantity1
installation depth51 mm
product brand nameSENTRON
● for signal <1>7 mA
Packaging Dimension78,00 x 111,00 x 136,00
Product DescriptionSENTRON, measuring device, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/ active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, screw terminals
Product designation7KM PAC3200
Voltmeter (EF006560)false
● Full-scale value500 ms
Design of the productbasic
design of the displayLCD
● for pulse emitteraccording to IEC62053-31
Digital output versionswitching or pulse output function
Ampere meter (EF006555)false
Height / of the display54 mm
Product Lifecycle (PLM)PM300:Active Product
● at DC / rated value24 V
General Product ApprovalDeclaration of Conformity
Product type designationMeasuring instrument
Pulse counter (EF006559)false
number of digital inputs1
Measurable supply voltage
Refresh time / on display
Suitability for operationInstallation in stationary control panels in closed rooms
number of digital outputs1
● 1 / for fast Ethernet10 Mbit/s
Apparent power consumption
Export Control RegulationsAL : N / ECCN : EAR99
Frequency meter (EF006558)false
Vertical screen resolution96
design of the power supplyWide-range power supply
● Width / of the display72 mm
Horizontal image resolution128
Standard lead time ex-works14 Day/Days
Surcharge for Raw MaterialsNone
● 1 / at AC / Rated value1 A
● 2 / at AC / Rated value5 A
Blind power meter (EF006556)false
Package size unit of measureMM
Type of electrical connection
● at AWG conductors / solid2x 24 ... 18
● for EMC against unloadingIEC 61000-4-2: 2001-04
Mounting type / panel mountingYes
Product Dimensions (W x L x H)Not available
Refresh time / at the interface
Input current / at digital input
Input voltage / at digital input
Output delay / at digital output
Type of measured value detectioncomplete
adjustable time period / minimum10 ms
● for EMC for industrial sectorIEC 61000-6-2 respectively IEC 61326-1:2005, table 2
● for EMC against surge voltagesIEC 61000-4-5: 2001-12
● of the fast Ethernet interfaceRJ45 (8P8C)
Input delay time / at digital input
Relative measurable current / at AC
● Protection class IP / Rear sideIP20
● for signal <0> to <1> / maximum5 ms
● for signal <1> to <0> / maximum5 ms
● with expansion module / maximum8 V·A
Ambient temperature / during storage
● for environmental coldness checkIEC 60068-2-1
● for environmental dry heat checkIEC 60068-2-2
Article Number (Market Facing Number)7KM2112-0BA00-3AA0
Ambient temperature / during operation
Supply voltage frequency / rated value
WEEE (2012/19/EU) Take-Back ObligationYes
With rotational speed meter (EF006557)false
● automatic line frequency detectionYes
● protection class IP / on the frontIP65
● without expansion module / typical6 V·A
Measuring category / for supply voltageCATIII
Type of voltage / of the supply voltageAC/DC
Color / of the background of the displaywhite
Measuring category / for digital signalsCATII
● product function / pulse measurementYes
Measurable line frequency / initial value45 Hz
● at the measurement inputs for voltagescrew-type terminals
● between (PE)N and L / at AC / maximum480 V
● between (PE)N and L / at AC / minimum40 V
● for EMC against high frequency fieldsIEC 61000-4-3: 2006-02
● product function / current measurementYes
● product function / voltage measurementYes
Operating mode for measured value detection
Reference condition / for metering accuracyAcc. to IEC62053-22 and IEC62053-23
● initial value for signal<1>-recognition13 V
● reference code / acc. to DIN EN 61346-2P
Design of cable / connectable / Twisted pairYes
Internal resistance / at the digital outputs55 Ω
Measurable line frequency / Full-scale value65 Hz
Measuring category / for current measurementCATIII
Measuring category / for voltage measurementCATIII
Number of interfaces / acc. to Fast Ethernet1
Type of connectable conductor cross-sections
property of the output / short-circuit proofYes
● at the Ethernet interface / is supportedMODBUS TCP
● at the digital outputs / at DC / maximum100 mA
● product function / frequency measurementYes
Effective power measurement device (EF006561)false
Measuring procedure / for current measurementTRMS
Measuring procedure / for voltage measurementRMS
● for cyclic, environmental damp heat checkIEC 60068-2-30
● Full-scale value for signal<0> recognition8 V
● finely stranded / with core end processing1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²)
● product function / active power measurementYes
Continuous current / at AC / maximum permissible10 A
Zero-point suppression / for current measurement0,1 ... 10 %
● at digital output / for signal <1> / maximum27 mA
Switching frequency / at digital output / maximum17 Hz
● at digital output / with signal <0> / maximum0.2 mA
● at the measurement inputs for current / solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● at the measurement inputs for voltage / solid1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²)
● product function / reactive power measurementYes
Size of Power Monitoring Device / company-specificsize 96
● between the outer conductors / at AC / maximum831 V
● between the outer conductors / at AC / minimum70 V
● for EMC against voltage drops and interruptionsIEC 61000-4-11: 2004-03
Operating resource protection class / when installedII
● Certificate of suitability / as approval for USAUL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
● between (PE)N and L / at AC / maximum rated value400 V
Relative symmetrical tolerance / of the supply voltage10 %
● Certificate of suitability / as approval for CanadaUL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04
National language / on the display screen / is supportedger, en, fr, spa, ita, por, tur, chi
Consumed active power / for current measurement / per phase115 mW
Installation altitude / at height above sea level / maximum2 000 m
● for EMC against quick, transient electrical disturbancesIEC 61000-4-4: 2005-07
● between the outer conductors / at AC / maximum rated value690 V
● Certificate of suitability / as EC declaration of conformityIEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1"
● for EMC against conducted LF disturbance variables (industry)IEC 61000-6-4, Group 1 Klasse A / CISPR11 Gruppe 1 Klasse A FCC Part 15 Subpart B Class A
● for EMC against conducted disturbance variables via HF fieldsIEC 61000-4-6: 2001-12
Operating voltage / as output voltage / at DC / maximum permissible30 V
Type of connectable conductor cross-sections / at the digital inputs
Type of connectable conductor cross-sections / at the digital outputs
● at the measurement inputs for current / at AWG conductors / solid2x 20 to 14
● at the measurement inputs for voltage / at AWG conductors / solid2x 20 to 14
Compliance with the substance restrictions according to RoHS directiveSince: 14.09.2007
Current measuring range extension / with external current transformersYes
Voltage measuring range extension / with external voltage transformersYes
● for EMC against magnetic fields with power engineering frequenciesIEC 61000-4-8: 2001-03
Relative humidity / at 25 °C / without condensation / during operation
REACH Art. 33 Duty to inform according to the current list of candidatesLead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.
Supply voltage / between the outer conductors / at AC / maximum permissible831 V
Type of connectable conductor cross-sections / at the inputs for supply voltage
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750P
● Formula for relative total measurement inaccuracy / for measured variable output+/- 0,5 %
Outer conductors and neutral conductors internal resistance / for voltage measurement1.05 MΩ
● Formula for relative total measurement inaccuracy / for measured variable current+/- 0,2 %
● Formula for relative total measurement inaccuracy / for measured variable voltage+/- 0,3 %
● at the measurement inputs for current / finely stranded / with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● at the measurement inputs for voltage / finely stranded / with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● Formula for relative total measurement inaccuracy / for measured variable active energyCl. 0.5 acc. to... IEC62053-22
● Formula for relative total measurement inaccuracy / for measured variable output factor+/- 0,5 %
● Formula for relative total measurement inaccuracy / for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
General Product ApprovalDeclaration of ConformityTest CertificatesotherType Test Certificates/Test ReportConfirmationManufacturer DeclarationGeneral Product Approval

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top