| Parameter | Value |
|---|---|
| Value | |
| EAN | 4011209774438 |
| UPC | 783087916036 |
| ETIM | 4 |
| MTBF | 185.8 y |
| Depth | 56 mm |
| Width | 96 mm |
| Height | 96 mm |
| UNSPSC | 14 |
| eClass | 6 |
| Protocol | |
| Standard | |
| Group Code | P360 |
| net weight | 470 g |
| Price Group | 15N |
| ● maximum | 65 Hz |
| ● minimum | 45 Hz |
| Cutout width | 92 mm |
| Metal Factor | None |
| Cutout height | 92 mm |
| Product Group | 5308 |
| Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. |
| Quantity Unit | 1 Piece |
| Transfer rate | |
| Voltage curve | Sinusoidal or distorted |
| Commodity Code | 90303100 |
| Output current | |
| Product family | 7KM PAC Measuring Devices |
| Pulse duration | |
| number of keys | 4 |
| Net Weight (kg) | 0,427 Kg |
| ● is supported | Modbus TCP |
| ● set at 50 Hz | No |
| ● set to 60 Hz | No |
| Country of origin | Hungary |
| mounting position | vertical |
| ● for free fall | IEC 60068-2-32: 1975 |
| ● initial value | 30 ms |
| LKZ_FDB/ CatalogID | LV10.1 |
| Measurable current | |
| Packaging Quantity | 1 |
| installation depth | 51 mm |
| product brand name | SENTRON |
| ● for signal <1> | 7 mA |
| Packaging Dimension | 115,00 x 135,00 x 80,00 |
| Product Description | SENTRON, measuring device, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optional Modbus RTU / PROFINET / PROFIBUS, apparent/ active/reactive energy, class 0.5 acc. to IEC61557-12 or class 0.5s acc. to IEC62053-22, wide-range pwr sup. unit AC/DC, ring cable lug connection |
| Product designation | 7KM PAC3200 |
| Voltmeter (EF006560) | false |
| ● Full-scale value | 500 ms |
| Design of the product | basic |
| design of the display | LCD |
| ● for pulse emitter | according to IEC62053-31 |
| Digital output version | switching or pulse output function |
| Ampere meter (EF006555) | false |
| Height / of the display | 54 mm |
| Product Lifecycle (PLM) | PM300:Active Product |
| ● at DC / rated value | 24 V |
| General Product Approval | Declaration of Conformity |
| Product type designation | Measuring instrument |
| Pulse counter (EF006559) | false |
| number of digital inputs | 1 |
| Measurable supply voltage | |
| Refresh time / on display | |
| Suitability for operation | Installation in stationary control panels in closed rooms |
| number of digital outputs | 1 |
| ● 1 / for fast Ethernet | 10 Mbit/s |
| Apparent power consumption | |
| Export Control Regulations | AL : N / ECCN : EAR99 |
| Frequency meter (EF006558) | false |
| Vertical screen resolution | 96 |
| design of the power supply | Wide-range power supply |
| ● Width / of the display | 72 mm |
| Horizontal image resolution | 128 |
| Standard lead time ex-works | 2 Day/Days |
| Surcharge for Raw Materials | None |
| ● 1 / at AC / Rated value | 1 A |
| ● 2 / at AC / Rated value | 5 A |
| Blind power meter (EF006556) | false |
| Package size unit of measure | MM |
| Type of electrical connection | |
| ● for EMC against unloading | IEC 61000-4-2: 2001-04 |
| Mounting type / panel mounting | Yes |
| Product Dimensions (W x L x H) | Not available |
| Refresh time / at the interface | |
| Input current / at digital input | |
| Input voltage / at digital input | |
| Output delay / at digital output | |
| Type of measured value detection | complete |
| adjustable time period / minimum | 10 ms |
| ● for EMC for industrial sector | IEC 61000-6-2 respectively IEC 61326-1:2005, table 2 |
| ● for EMC against surge voltages | IEC 61000-4-5: 2001-12 |
| Input delay time / at digital input | |
| Relative measurable current / at AC | |
| ● for signal <0> to <1> / maximum | 5 ms |
| ● for signal <1> to <0> / maximum | 5 ms |
| ● with expansion module / maximum | 8 V·A |
| Ambient temperature / during storage | |
| ● for environmental coldness check | IEC 60068-2-1 |
| ● for environmental dry heat check | IEC 60068-2-2 |
| Article Number (Market Facing Number) | 7KM2112-0BA00-2AA0 |
| Ambient temperature / during operation | |
| Supply voltage frequency / rated value | |
| WEEE (2012/19/EU) Take-Back Obligation | Yes |
| With rotational speed meter (EF006557) | false |
| ● automatic line frequency detection | Yes |
| ● protection class IP / on the front | IP65 |
| ● without expansion module / typical | 6 V·A |
| Measuring category / for supply voltage | CATIII |
| Type of voltage / of the supply voltage | AC/DC |
| Color / of the background of the display | white |
| Measuring category / for digital signals | CATII |
| ● product function / pulse measurement | Yes |
| Measurable line frequency / initial value | 45 Hz |
| ● at the measurement inputs for voltage | Ring cable lug connection |
| ● between (PE)N and L / at AC / maximum | 480 V |
| ● between (PE)N and L / at AC / minimum | 40 V |
| ● for EMC against high frequency fields | IEC 61000-4-3: 2006-02 |
| ● product function / current measurement | Yes |
| ● product function / voltage measurement | Yes |
| Operating mode for measured value detection | |
| Reference condition / for metering accuracy | Acc. to IEC62053-22 and IEC62053-23 |
| ● initial value for signal<1>-recognition | 13 V |
| ● reference code / acc. to DIN EN 61346-2 | P |
| Design of cable / connectable / Twisted pair | Yes |
| Internal resistance / at the digital outputs | 55 Ω |
| Measurable line frequency / Full-scale value | 65 Hz |
| Measuring category / for current measurement | CATIII |
| Measuring category / for voltage measurement | CATIII |
| Number of interfaces / acc. to Fast Ethernet | 1 |
| property of the output / short-circuit proof | Yes |
| ● at the Ethernet interface / is supported | MODBUS TCP |
| ● at the digital outputs / at DC / maximum | 100 mA |
| ● product function / frequency measurement | Yes |
| Effective power measurement device (EF006561) | false |
| Measuring procedure / for current measurement | TRMS |
| Measuring procedure / for voltage measurement | RMS |
| ● for cyclic, environmental damp heat check | IEC 60068-2-30 |
| ● Full-scale value for signal<0> recognition | 8 V |
| ● product function / active power measurement | Yes |
| Continuous current / at AC / maximum permissible | 10 A |
| Zero-point suppression / for current measurement | 0,1 ... 10 % |
| ● at digital output / for signal <1> / maximum | 27 mA |
| ● at digital output / for signal <1> / minimum | 10 mA |
| Switching frequency / at digital output / maximum | 17 Hz |
| ● at digital output / with signal <0> / maximum | 0.2 mA |
| ● product function / reactive power measurement | Yes |
| Size of Power Monitoring Device / company-specific | size 96 |
| ● between the outer conductors / at AC / maximum | 831 V |
| ● between the outer conductors / at AC / minimum | 70 V |
| ● for EMC against voltage drops and interruptions | IEC 61000-4-11: 2004-03 |
| Operating resource protection class / when installed | II |
| ● Certificate of suitability / as approval for USA | UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 |
| ● between (PE)N and L / at AC / maximum rated value | 400 V |
| Relative symmetrical tolerance / of the supply voltage | 10 % |
| ● Certificate of suitability / as approval for Canada | UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 |
| National language / on the display screen / is supported | ger, en, fr, spa, ita, por, tur, chi |
| Consumed active power / for current measurement / per phase | 115 mW |
| Installation altitude / at height above sea level / maximum | 2 000 m |
| ● for EMC against quick, transient electrical disturbances | IEC 61000-4-4: 2005-07 |
| ● between the outer conductors / at AC / maximum rated value | 690 V |
| ● Certificate of suitability / as EC declaration of conformity | IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1" |
| ● for EMC against conducted LF disturbance variables (industry) | IEC 61000-6-4, Group 1 Klasse A / CISPR11 Gruppe 1 Klasse A FCC Part 15 Subpart B Class A |
| ● for EMC against conducted disturbance variables via HF fields | IEC 61000-4-6: 2001-12 |
| Operating voltage / as output voltage / at DC / maximum permissible | 30 V |
| Compliance with the substance restrictions according to RoHS directive | Since: 01.03.2008 |
| Current measuring range extension / with external current transformers | Yes |
| Voltage measuring range extension / with external voltage transformers | Yes |
| ● for EMC against magnetic fields with power engineering frequencies | IEC 61000-4-8: 2001-03 |
| Relative humidity / at 25 °C / without condensation / during operation | |
| REACH Art. 33 Duty to inform according to the current list of candidates | Lead CAS-No. 7439-92-1 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):LeadBased on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.Lead monoxide (lead ... CAS-No. 1317-36-8 > 0, 1 % (w / w)Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):Lead monoxide (lead oxide)Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation. |
| Supply voltage / between the outer conductors / at AC / maximum permissible | 831 V |
| Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 | P |
| ● Formula for relative total measurement inaccuracy / for measured variable output | +/- 0,5 % |
| Outer conductors and neutral conductors internal resistance / for voltage measurement | 1.05 MΩ |
| ● Formula for relative total measurement inaccuracy / for measured variable current | +/- 0,2 % |
| ● Formula for relative total measurement inaccuracy / for measured variable voltage | +/- 0,3 % |
| General Product ApprovalDeclaration of ConformityotherConfirmationManufacturer Declaration | General Product Approval |
| ● Formula for relative total measurement inaccuracy / for measured variable active energy | Cl. 0.5 acc. to... IEC62053-22 |
| ● Formula for relative total measurement inaccuracy / for measured variable output factor | +/- 0,5 % |
| ● Formula for relative total measurement inaccuracy / for measured variable reactive energy | Class 2 according to IEC61557-12 and/or IEC62053-23 |
Technical specifications and performance data
Installation and operation guide