| Parameter | Value |
|---|---|
| EAN | 4048879759007 |
| Form | 88011 |
| eClass | 27279218 |
| Weight: | 0.026 kg |
| Art.No.: | 7700-88011-U040030 |
| Material | PUR |
| Standards | DIN EN 61076-2-104 (M8) |
| Protection | IP65, IP66K, IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Jacket Color | yellow |
| No. of poles | 4 |
| Test voltage | 2 000 V AC |
| Color (jacket) | yellow |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Torsion stress | ±180°/m |
| Diameter (core) | 1×4×AWG22/19 (0.382) |
| Material (wire) | Cu wire, bare |
| Mounting method | inserted, tightened |
| Nominal voltage | 300 V AC |
| Resistor (core) | max. 46.9 Ω/km (20 °C) |
| Approval (cable) | UL (AWM-Style 20626/1731), CSA; CE conform |
| Locking material | Brass, nickel-plated (screw), Zinc die casting, nickel-plated (nut) |
| Locking of ports | Screw thread M8 × 1 mm (recommended torque 0.4 Nm) self-securing |
| Pollution Degree | 3 |
| Compression gland | M8 (SW9) |
| Material (jacket) | TPE |
| Operating voltage | max. 50 V AC/60 V DC |
| Outer-Ø (jacket) | 5.3 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| Cable weight [g/m] | 49,50 |
| thermal resistance | flame retardant |
| Bend radius (fixed) | 5 × outer Ø |
| Construction (core) | 19 × 0.16 mm (multi-strand wire class 5) |
| Rated surge voltage | 1.5 kV |
| chemical resistance | good resistance to oil, gasoline and chemicals |
| Bend radius (moving) | 10 × outer Ø |
| Cable identification | U04 |
| Current load capacity | to DIN VDE 0298-4 |
| Single wire Ø (core) | 0.16 mm |
| Stranding combination | 4 wires twisted |
| customs tariff number | 85444290 |
| Wire-Ø incl. isolation | 1.27m ±5% |
| Color/numbering of wires | br, bk, bl, wh |
| Material (wire isolation) | semi-rigid PVC |
| Temperature range (fixed) | -40...+105 °C |
| Temperature range (mobile) | -20...+90 °C |
| Operating current per contact | max. 4 A |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| suitable for corrugated tube (internal Ø) | 10 mm |
Technical specifications and performance data