| Parameter | Value |
|---|---|
| max. 1000 mOhm/m @ 100 MHz | |
| EAN | 4048879696951 |
| Form | 51001 |
| Coding | X-coded |
| Shield | yes |
| eClass | 27061801 |
| Material | PUR |
| Outer Ø | 7.4 mm ±5% |
| Standards | DIN EN 61076-2-109 (M12) |
| Protection | IP67 inserted and tightened (EN 60529) |
| LED display | no |
| Cable number | S4X |
| Jacket Color | blue |
| No. of poles | 8 |
| Test voltage | max. 1.5 kV AC (2s) |
| Configuration | fully used |
| Torsion speed | 60 cycles/min |
| Transfer rate | 10 Gbit/s |
| Material group | IEC 60664-1, category I |
| Packaging unit | 1 |
| Wire isolation | HDPE (whbl, bl, whor, or, whgn, gn, whbr, br) |
| Diameter (core) | 4× 2× 0.14 mm² |
| Material (wire) | Cu wire, tin plated |
| Mounting method | inserted, tightened |
| Nominal voltage | 600 V |
| Resistor (core) | max. 140 Ohm/km |
| Approval (cable) | UL (AWM-Style 2463/11547), CSA |
| Locking material | Zinc die casting, matte nickel plated |
| Locking of ports | Screw thread (M12×1 mm) recommended torque 0.6 Nm, self-securing |
| Pollution Degree | 3 |
| Compression gland | M12 (SW13) |
| Material (jacket) | TPE (UL/CSA) |
| Operating voltage | max. 50 V AC/60 V DC |
| Outer-Ø (jacket) | 7.4 mm ±5% |
| Temperature range | -25...+85 °C, depending on cable quality |
| country of origin | DE |
| C-track properties | 1 Mio. |
| Cable weight [g/m] | 65,48 |
| thermal resistance | flame retardant |
| Bend radius (fixed) | 5× outer Ø |
| Construction (core) | 7× 0.16 mm |
| Rated surge voltage | 1.5 kV |
| Transfer parameters | CAT6, Class EA (ISO/IEC 11801:2002), (EN 50173-1) |
| Bend radius (moving) | 10× outer Ø |
| Cable identification | S4X |
| optical shield cover | min. 75% |
| No. of torsion cycles | max. 3 Mio. (25 °C) |
| No./diameter of wires | 4× 2× 0.14 mm² |
| Single wire Ø (core) | 0.16 mm |
| customs tariff number | 85444290 |
| Acceleration (C-track) | max. 2.4 m/s² |
| Travel speed (C-track) | max. 1.2 m/s |
| Wire-Ø incl. isolation | 0.9 mm ±5% |
| Color/numbering of wires | (wh-bl, bl) + (wh-or, or) + (wh-gn, gn) + (wh-br, br) |
| Material (wire isolation) | HDPE |
| Temperature range (fixed) | -40...+80 °C |
| Temperature range (mobile) | -20...+80 °C |
| Operating current per contact | max. 0.5 A |
| Traversing distance (C-track) | max. 0.6 m |
| No. of bending cycles (C-track) | max. 10 Mio. (25 °C) |
| Operating voltage (only UL listed) | max. 30 V AC/DC |
| suitable for corrugated tube (internal Ø) | without |
Technical specifications and performance data